Evidence map›Paper›PMID 34469530›Full record

ArticleMilitary medicine2021

Reducing Setup and Turnover Times in the OR With an Innovative Sterilization Container: Implications for the COVID-19 Era Military Medicine.

David F Bradley, Kenneth Romito, James Dockery, Lance Taylor, Nicholas ONeel, Jose Rodriguez, Laura A Talbot

Abstract read
In one paragraph

Article in Military medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

David F BradleyUniformed Services University of the Health Sciences, Graduate School of Nursing, Bethesda, MD 20814, USA.
Kenneth RomitoDepartment of Perioperative Services, Tripler Army Medical Center, Honolulu, HI 96859, USA.
James DockeryDepartment of Perioperative Services, Brooke Army Medical Center, JBSA-Fort Sam Houston, TX 78234, USA.
Lance TaylorDepartment of Perioperative Services, Defense Health Agency, Falls Church, VA 22042, USA.
Nicholas ONeelDepartment of Perioperative Services, Brooke Army Medical Center, JBSA-Fort Sam Houston, TX 78234, USA.
Jose RodriguezUniformed Services University of the Health Sciences, Graduate School of Nursing, Bethesda, MD 20814, USA.
Laura A TalbotDepartment of Neurology, University of Tennessee Health Science Center, College of Medicine, Memphis, TN 38163, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe global 2019 coronavirus pandemic (COVID-19) is setting unprecedented demands on the nation and the military and surgical services. Surgical demands include a large backlog of surgical cases, strain on available resources, and the need for additional measures to prevent exposure. The purpose of this project was to evaluate the feasibility, duration, adverse events, and potential gains associated with using a Turbett Sterilization Pod (TSP) for total joint replacements. MATERIALS AND

methodsA multidisciplinary team used the Plan-Do-Study-Act model to guide this project. A time-motion study was completed in the operating room (OR) to measure the average time required to set up surgical instrumentation for total joint replacement cases that required 12 or more instrument trays. We compared the amount of time it took to complete the setting up of instrumentation using the traditional method versus the TSP method. The traditional method consisted of unwrapping each surgical tray, checking for holes in the blue wrapper, and placing the tray on the back table. In the case of the TSP, the door of the pod was opened, and the instrument trays were transferred directly to the back table. We measured the time the staff took to perform the task using each of these methods.

resultsWhen compared to the traditional method, the use of the TSP resulted in improved turnover time, decreased room setup time, reduced environmental waste, and eliminated both the effect of damage to wrappers and the time previously spent wrapping surgical trays.

conclusionThe TSP minimizes the time needed by the staff to set up an OR suite for a total joint replacement, therefore permitting them to focus more on direct patient care. This time improvement suggests that all surgical specialties, including those requiring greater than 12 traditional instrument sets, may experience reduced turnover time between cases. The use of the TSP is one means to help rectify the OR backlog brought on by COVID-19.

Indexed as

COVID-19Military MedicineCost SavingsHumansOperating RoomsSARS-CoV-2SterilizationSurgical Instruments

Identifiers

PMID34469530
PMCPMC8499844

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.