Evidence map›Paper›PMID 34462876›Full record

ArticlePharmaceutical research2021

Advancement of the Infant Air-Jet Dry Powder Inhaler (DPI): Evaluation of Different Positive-Pressure Air Sources and Flow Rates.

Connor Howe, Mohammad A M Momin, Dale R Farkas, Serena Bonasera, Michael Hindle, P Worth Longest

Abstract read
In one paragraph

Article in Pharmaceutical research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Dry powder inhaler design and particle technology in enhancing Pulmonary drug deposition: challenges and future strategies.Daru : journal of Faculty of Pharmacy, Tehran University of Medical Sciences · 2024
    Review
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Journal of aerosol medicine and pulmonary drug delivery · 2022
    Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Connor HoweDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA, 23284-3015, USA.
Mohammad A M MominDepartment of Pharmaceutics, Virginia Commonwealth University, 410 North 12th Street, P.O. Box 980533, Richmond, VA, 23298-0533, USA.
Dale R FarkasDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA, 23284-3015, USA.
Serena BonaseraDepartment of Pharmaceutics, Virginia Commonwealth University, 410 North 12th Street, P.O. Box 980533, Richmond, VA, 23298-0533, USA.
Michael HindleDepartment of Pharmaceutics, Virginia Commonwealth University, 410 North 12th Street, P.O. Box 980533, Richmond, VA, 23298-0533, USA.
P Worth LongestDepartment of Mechanical and Nuclear Engineering, Virginia Commonwealth University, 401 West Main Street, P.O. Box 843015, Richmond, VA, 23284-3015, USA. pwlongest@vcu.edu.

Funding

High Efficiency Delivery of Surfactant Aerosols to Infants without IntubationR01HL139673 · NHLBI · VIRGINIA COMMONWEALTH UNIVERSITY · PI HINDLE, MICHAEL, LONGEST, P. WORTH · 2018 to 2021
$2.8M
High Efficiency Inhalation Delivery of Tobramycin for Children with Cystic FibrosisR01HD087339 · NICHD · VIRGINIA COMMONWEALTH UNIVERSITY · PI HINDLE, MICHAEL, LONGEST, P. WORTH · 2017 to 2021
$2.5M
NHLBI NIH HHS R01 HL139673NICHD NIH HHS R01 HD087339
6 · The paper itself

Abstract

purposeIn order to improve the delivery of dry powder aerosol formulations to the lungs of infants, this study implemented an infant air-jet platform and explored the effects of different air sources, flow rates, and pulmonary mechanics on aerosolization performance and aerosol delivery through a preterm nose-throat (NT) in vitro model.

methodsThe infant air-jet platform was actuated with a positive-pressure air source that delivered the aerosol and provided a full inhalation breath. Three different air sources were developed to provide highly controllable positive-pressure air actuations (using actuation volumes of ~10 mL for the preterm model). While providing different flow waveform shapes, the three air sources were calibrated to produce the same flow rate magnitude (Q90: 90th percentile of flow rate). Multiple air-jet DPI designs were coupled with the air sources and evaluated with a model spray-dried excipient enhanced growth formulation.

resultsCompared to other designs, the D1-Single air-jet DPI provided improved performance with low variability across all three air sources. With the tested D1-Single air-jet and Timer air source, reducing the flow rate from 4 to 1.7 L/min marginally decreased the aerosol size and significantly increased the lung delivery efficiency above 50% of the loaded dose. These results were not impacted by the presence of downstream pulmonary mechanics (resistance and compliance model).

conclusionsThe selected design was capable of providing an estimated >50% lung delivery efficiency of a model spray-dried formulation and was not influenced by the air source, thereby enabling greater flexibility for platform deployment in different environments.

Indexed as

Administration, InhalationAerosolsChemistry, PharmaceuticalDry Powder InhalersEquipment DesignExcipientsHumansInfantLungNoseParticle SizePowdersAerosolsExcipientsPowdershigh efficiency aerosolizationinfant DPIinline DPInose-to-lung aerosol deliverypositive pressure DPItrans-nasal aerosol delivery

Identifiers

PMID34462876
PMCPMC8642819

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.