Evidence map›Paper›PMID 34460758›Full record

ArticleJournal of imaging2021

Non-Contact Automatic Vital Signs Monitoring of Infants in a Neonatal Intensive Care Unit Based on Neural Networks.

Fatema-Tuz-Zohra Khanam, Asanka G Perera, Ali Al-Naji, Kim Gibson, Javaan Chahl

Open access · goldAbstract read
In one paragraph

Article in Journal of imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 19 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed, 2 pooled it
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 2 syntheses or guidelines pooled it, 55 citations in OpenAlex.

  1. Pooled it
  2. Pooled it
  3. Artificial intelligence and digital technologies transforming neonatal respiratory assessment: a scoping review.Journal of perinatology : official journal of the California Perinatal Association · 2026
    Review
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Review
  10. Review
  11. Article
  12. Review
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 2 countries.

Fatema-Tuz-Zohra KhanamUniSA STEM, Mawson Lakes Campus, University of South Australia, Mawson Lakes, SA 5095, Australia.
Asanka G PereraUniSA STEM, Mawson Lakes Campus, University of South Australia, Mawson Lakes, SA 5095, Australia.ORCID 0000-0003-4021-3943
Ali Al-NajiUniSA STEM, Mawson Lakes Campus, University of South Australia, Mawson Lakes, SA 5095, Australia.ORCID 0000-0002-8840-9235
Kim GibsonClinical and Health Sciences, City East Campus, University of South Australia, North Terrace, Adelaide, SA 5000, Australia.
Javaan ChahlUniSA STEM, Mawson Lakes Campus, University of South Australia, Mawson Lakes, SA 5095, Australia.ORCID 0000-0001-6496-0543
University of South Australia · AU

Funding

University of South Australia Research Training Program domestic (RTPd) scholarship
6 · The paper itself

Abstract

Infants with fragile skin are patients who would benefit from non-contact vital sign monitoring due to the avoidance of potentially harmful adhesive electrodes and cables. Non-contact vital signs monitoring has been studied in clinical settings in recent decades. However, studies on infants in the Neonatal Intensive Care Unit (NICU) are still limited. Therefore, we conducted a single-center study to remotely monitor the heart rate (HR) and respiratory rate (RR) of seven infants in NICU using a digital camera. The region of interest (ROI) was automatically selected using a convolutional neural network and signal decomposition was used to minimize the noise artefacts. The experimental results have been validated with the reference data obtained from an ECG monitor. They showed a strong correlation using the Pearson correlation coefficients (PCC) of 0.9864 and 0.9453 for HR and RR, respectively, and a lower error rate with RMSE 2.23 beats/min and 2.69 breaths/min between measured data and reference data. A Bland-Altman analysis of the data also presented a close correlation between measured data and reference data for both HR and RR. Therefore, this technique may be applicable in clinical environments as an economical, non-contact, and easily deployable monitoring system, and it also represents a potential application in home health monitoring.

Indexed as

convolutional neural networkheart rateNICUrespiratory ratesignal decomposition

Identifiers

PMID34460758
PMCPMC8404938
OpenAlexW3186419559

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.