ArticleSheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi2021
[Numerical study on the effect of the geometry size of multi-chamber infusion bag on its bursting force].
Article in Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 0 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This study explored the variation of bursting force of multi-chamber infusion bag with different geometry size, providing guidance for its optimal design. Models of single-chamber infusion bag with different size were established. The finite element based on fluid cavity method was adopted to calculate the fluid-solid coupling deformation process of infusion bag to obtain corresponding critical bursting force. As a result, we proposed an empirical formula predicting the critical bursting force of one chamber infusion bag with specified geometry size. Besides, a theoretical analysis, which determines the force condition of three chamber infusion bag when falling from high altitude, was conducted. The proportion of force loaded on different chamber was gained. The results indicated that critical bursting force is positively related to the length and width of the chamber, and negatively related to the height of the chamber. While the infusion bag falling, the impact force loaded on each chamber is proportional to the total liquid within it. To raise the critical bursting force of in fusion bag, a greater length and width corresponding to reduced height are recommended considering the volume of liquid needed to be filled in.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.