Evidence map›Paper›PMID 34459080›Full record

ArticleAngewandte Chemie (International ed. in English)2021

Background-Free Proton NMR Spectroscopy with Radiofrequency Amplification by Stimulated Emission Radiation.

Baptiste Joalland, Thomas Theis, Stephan Appelt, Eduard Y Chekmenev

Abstract read
In one paragraph

Article in Angewandte Chemie (International ed. in English), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Rapid RASER MRI.Angewandte Chemie (International ed. in English) · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Toward Ultra-High-Quality-Factor Wireless Masing Magnetic Resonance Sensing.Angewandte Chemie (International ed. in English) · 2024
    Article
  6. Article
  7. Journal of the American Chemical Society · 2023
    Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Baptiste JoallandDepartment of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), 5101 Cass Ave, Detroit, MI, 48202, USA.ORCID 0000-0003-4116-6122
Thomas TheisDepartment of Chemistry, North Carolina State University, Raleigh, North Carolina, 27695-8204, USA.ORCID 0000-0001-6779-9978
Stephan AppeltInstitut für Technische und Makromolekulare Chemie (ITMC), RWTH Aachen University, 52056, Aachen, Germany.ORCID 0000-0001-6036-2167
Eduard Y ChekmenevDepartment of Chemistry, Integrative Biosciences (Ibio), Wayne State University, Karmanos Cancer Institute (KCI), 5101 Cass Ave, Detroit, MI, 48202, USA.ORCID 0000-0002-8745-8801

Funding

Molecular MRI of Brain Metabolism Enabled by Long-Lived Spin StatesR01EB029829 · NIBIB · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI THEIS, THOMAS · 2020 to 2020
$807k
Molecular imaging with a hyperpolarized Vitamin ShotR21EB025313 · NIBIB · NORTH CAROLINA STATE UNIVERSITY RALEIGH · PI THEIS, THOMAS · 2018 to 2019
$661k
Hyperpolarized Diethyl Ether for Sub-second Pulmonary MRIR21HL154032 · NHLBI · WAYNE STATE UNIVERSITY · PI CHEKMENEV, EDUARD · 2020 to 2021
$419k
Magnetic Resonance Spectroscopy and Molecular Imaging of Metabolic Pathways in CancerR21CA220137 · NCI · WAYNE STATE UNIVERSITY · PI CHEKMENEV, EDUARD · 2017 to 2019
$390k
congressionally directed medical research programs W81XWH-15-1-0271congressionally directed medical research programs W81XWH-20-10576directorate for mathematical and physical sciences CHE-1904780mallinckrodt foundationNCI NIH HHS 1R21CA220137NCI NIH HHS R21 CA220137NHLBI NIH HHS R21 HL154032NIBIB NIH HHS R01 EB029829NIBIB NIH HHS R01EB029829NIBIB NIH HHS R21 EB025313NIBIB NIH HHS R21EB025313north carolina biotechnology center
6 · The paper itself

Abstract

We report on the utility of Radiofrequency Amplification by Stimulated Emission Radiation (RASER) for background-free proton detection of hyperpolarized biomolecules. We performed hyperpolarization of ≈0.3 M ethyl acetate via pairwise parahydrogen addition to vinyl acetate. A proton NMR signal with signal-to-noise ratio exceeding 100 000 was detected without radio-frequency excitation at the clinically relevant magnetic field of 1.4 T using a standard (non-cryogenic) inductive detector with quality factor of Q=68. No proton background signal was observed from protonated solvent (methanol) or other added co-solvents such as ethanol, water or bovine serum. Moreover, we demonstrate RASER detection without radio-frequency excitation of a bolus of hyperpolarized contrast agent in biological fluid. Completely background-free proton detection of hyperpolarized contrast agents in biological media paves the way to new applications in the areas of high-resolution NMR spectroscopy and in vivo spectroscopy and imaging.

Indexed as

Body FluidsContrast MediaHumansMagnetic FieldsProton Magnetic Resonance SpectroscopyContrast MediahyperpolarizationNMR spectroscopyparahydrogenRASER

Identifiers

PMID34459080
PMCPMC8629966

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.