New insights from broadband simulations into small overmoded smooth and corrugated terahertz waveguides and transitions for NMR-DNP.

F David Doty, Glenn N Doty, John P Staab, Yuriy Sizyuk, Paul D Ellis

Abstract read
In one paragraph

Article in Journal of magnetic resonance open, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

F David DotyDoty Scientific, Columbia SC, United States.
Glenn N DotyDoty Scientific, Columbia SC, United States.
John P StaabDoty Scientific, Columbia SC, United States.
Yuriy SizyukDoty Scientific, Columbia SC, United States.
Paul D EllisDoty Scientific, Columbia SC, United States.

Funding

A Novel Waveguide to Enable MAS-DNP-NMR in Standard-bore High-field MagnetsR44GM139468 · NIGMS · DOTY SCIENTIFIC, INC. · PI DOTY, FRANCIS DAVID · 2023 to 2025
$2.5M
Closed-Loop MAS-DNP-NMR at 30 K for Affordable Dramatic Gains in S/NR44GM108147 · NIGMS · DOTY SCIENTIFIC, INC. · PI DOTY, FRANCIS DAVID · 2015 to 2017
$2.1M
A Reliable Switched Angle Spinning (SAS) Probe with Gradients (PFG) for Proteins in Solid-State NMRR44GM130201 · NIGMS · DOTY SCIENTIFIC, INC. · PI DOTY, FRANCIS DAVID · 2021 to 2023
$2.0M
An H/F/X/Y Fast-MAS NMR Probe Particularly for Alzheimer's and Cancer ResearchR44GM119937 · NIGMS · DOTY SCIENTIFIC, INC. · PI DOTY, FRANCIS DAVID · 2020 to 2021
$2.0M
High-order Cavities for Enabling High-field MAS-DNP-NMR with Low-cost THz SourcesR43GM140650 · NIGMS · DOTY SCIENTIFIC, INC. · PI DOTY, FRANCIS DAVID · 2021 to 2021
$300k
A Novel Waveguide to Enable MAS-DNP-NMR in Standard-bore High-field MagnetsR43GM139468 · NIGMS · DOTY SCIENTIFIC, INC. · PI DOTY, FRANCIS DAVID · 2020 to 2020
$297k
A Novel Millimeter-wave (mmw) DNP/EPR Front-end Compatible with Versatile High-field NMR ProbesR43AG058519 · NIA · DOTY SCIENTIFIC, INC. · PI DOTY, FRANCIS DAVID · 2017 to 2017
$225k
A Millimeter-wave Tunable Cavity for Ultra-sensitive Solids and Liquids DNP-NMR at Low BudgetR41AG050394 · NIA · DOTY SCIENTIFIC, INC. · PI DOTY, FRANCIS DAVID · 2014 to 2014
$197k
NIA NIH HHS R41 AG050394NIA NIH HHS R43 AG058519NIGMS NIH HHS R43 GM139468NIGMS NIH HHS R43 GM140650NIGMS NIH HHS R44 GM108147NIGMS NIH HHS R44 GM119937NIGMS NIH HHS R44 GM130201NIGMS NIH HHS R44 GM139468
6 · The paper itself

Abstract

The primary impetus for the work reported in this paper is to develop efficient overmoded waveguides (OMWGs) that employ broadband downtaper transitions that would be compatible with the severe space constraints in high-field NB magnets. Further, it is essential these would be readily manufacturable, as high precision corrugated metallic downtapers for the sub-mmw regime are very difficult to produce. We have simulated numerous alternatives to corrugated circular OMWGs, including most of the previously reported alternatives (except for many of the low-power fiberoptics options) and several novel designs. We conclude that corrugated circular metallic OMWGs are the best of the reported options to date (except from a cost perspective) for diameters down to ~1.5

Indexed as

Corrugated wave guidesDowntapersNMR-DNPOvermoded Waveguides (OMWGs)

Identifiers

PMID34458877
PMCPMC8388244

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.