Evidence map›Paper›PMID 34458197›Full record

ArticleJournal of biomedical physics & engineering2021

Can Common Lead Apron in Testes Region Cause Radiation Dose Reduction during Chest CT Scan? A Patient Study.

Mohammad Kiapour, Kourosh Ebrahimnejad Gorji, Rahele Mehraeen, Naser Ghaemian, Fatemeh Niksirat Sustani, Razzagh Abedi-Firouzjah, Ali Shabestani Monfared

Open access · goldAbstract read
In one paragraph

Article in Journal of biomedical physics & engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 4 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Mohammad KiapourMSc, Student Research Committee, Babol University of Medical Sciences, Babol, Iran.
Kourosh Ebrahimnejad GorjiPhD, Department of Medical Physics Radiobiology and Radiation Protection, School of Medicine, Babol University of Medical Sciences, Babol, Iran.
Rahele MehraeenMD, Department of Pediatric Radiology, Babol University of Medical Sciences, Babol, Iran.
Naser GhaemianMD, Department of Radiology and Radiotherapy, School of Medicine, Babol University of Medical Sciences, Babol, Iran.
Fatemeh Niksirat SustaniMSc, Department of Medical Physics Radiobiology and Radiation Protection, School of Medicine, Babol University of Medical Sciences, Babol, Iran.
Razzagh Abedi-FirouzjahMSc, Department of Medical Physics Radiobiology and Radiation Protection, School of Medicine, Babol University of Medical Sciences, Babol, Iran.
Ali Shabestani MonfaredPhD, Cancer Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, Iran.
Babol University of Medical Sciences · IR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundComputed tomography (CT) is a routine procedure for diagnosing using ionization radiation which has hazardous effects especially on sensitive organs.

objectiveThe aim of this study was to quantify the dose reduction effect of lead apron shielding on the testicular region during routine chest CT scans. MATERIAL AND

methodsIn this measurement study, the routine chest CT examinations were performed for 30 male patients with common lead aprons folded and positioned in testis regions. The patient's mean body mass index (BMI) was 26.2 ± 4.6 kg/m

resultsThe radiation dose in the testicular regions was reduced from 0.46 ± 0.04 to 0.20 ± 0.04 mGy in the presence of lead apron shielding (p < 0.001), the reduction was equal to 56%. Furthermore, the heritable risk probability was obtained at 2.0 ×10

conclusionApplying common lead aprons as shielding in the testis regions of male patients undergoing chest CT scans can reduce the radiation doses significantly. Therefore, this shield can be recommended for routine chest CT examinations.

Indexed as

Chest CT ScanComputed TomographyLead ApronRadiation ProtectionTestisThermoluminescent Dosimetry

Identifiers

PMID34458197
PMCPMC8385221
OpenAlexW3183719434

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.