ArticleJournal of biomedical physics & engineering2021
Can Common Lead Apron in Testes Region Cause Radiation Dose Reduction during Chest CT Scan? A Patient Study.
Article in Journal of biomedical physics & engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 4 citations in OpenAlex.
- Paradigm shift in the application of patient contact shielding: a balancing act between tradition and progress.European radiology · 2026Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundComputed tomography (CT) is a routine procedure for diagnosing using ionization radiation which has hazardous effects especially on sensitive organs.
objectiveThe aim of this study was to quantify the dose reduction effect of lead apron shielding on the testicular region during routine chest CT scans. MATERIAL AND
methodsIn this measurement study, the routine chest CT examinations were performed for 30 male patients with common lead aprons folded and positioned in testis regions. The patient's mean body mass index (BMI) was 26.2 ± 4.6 kg/m
resultsThe radiation dose in the testicular regions was reduced from 0.46 ± 0.04 to 0.20 ± 0.04 mGy in the presence of lead apron shielding (p < 0.001), the reduction was equal to 56%. Furthermore, the heritable risk probability was obtained at 2.0 ×10
conclusionApplying common lead aprons as shielding in the testis regions of male patients undergoing chest CT scans can reduce the radiation doses significantly. Therefore, this shield can be recommended for routine chest CT examinations.