Evidence map›Paper›PMID 34457413›Full record

ArticleBiomedical optics express2021

Multiplex optical biosensors based on multi-pinhole interferometry.

Johannes Bläsi, Martina Gerken

Open access · goldAbstract read
In one paragraph

Article in Biomedical optics express, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
0.9field-weighted citation impact, top 26% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 13 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Johannes BläsiInstitute of Electrical Engineering and Information Technology, Kiel University, Kaiserstraße 2, 24143 Kiel, Germany.ORCID https://orcid.org/0000-0002-8379-4664
Martina GerkenInstitute of Electrical Engineering and Information Technology, Kiel University, Kaiserstraße 2, 24143 Kiel, Germany.ORCID https://orcid.org/0000-0002-4234-7833
Christian-Albrechts-Universität zu Kiel · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The application of new sensor technologies for frequent biomarker monitoring in combination with the leverage of artificial intelligence has great potential to improve the design and safety of health care. With current research efforts, the screening of tens of biomarkers at the point of care and immediate adjustment of therapy is coming within reach. Here we introduce an optical multiplexing approach based on multi-pinhole interference providing inherent differential referencing between a multitude of measurement fields on a surface. A theoretical study of an 11-plex and a 54-plex design is complemented with the experimental demonstration of the technique for a 3-field refractive index measurements and detection of human

Identifiers

PMID34457413
PMCPMC8367262
OpenAlexW3169073401

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.