ArticleBiomedical optics express2021
Retinal contour modelling to reproduce two-dimensional peripheral spherical equivalent refraction.
Article in Biomedical optics express, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed, 7 citations in OpenAlex.
- Individualized modeling for the peripheral optics of the human myopic eye.Biomedical optics express · 2023Article
- Photopic pupil size change in myopic orthokeratology and its influence on axial length elongation.International journal of ophthalmology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Reproduction of the peripheral spherical equivalent refraction (SER) in the eye model is critical for investigations in myopia control. Based on the derivation of a linear relationship between SER and the vergence of the wavefront at exit pupil center, a computing method is proposed to locate the retinal points to reproduce the two-dimensional (2D) distribution of SER. The method is validated by reproducing SER maps measured on both emmetropic and myopic eyes in a realistic eye model based on measurement data. By fitting the retinal points to a general ellipsoid, the limited capability of the general ellipsoid model in reproducing the 2D map of SER is calculated and compared with original data. The high accuracy in SER reproduction and low time-cost of the proposed retinal-locating method can help significantly improve the precision and accuracy of customized wide-angle eye modelling.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.