ArticleBiomedical optics express2021
Method of transmission filters to measure emission spectra in strongly scattering media.
Article in Biomedical optics express, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed.
- High-Speed Hyperspectral Imaging for Near Infrared Fluorescence and Environmental Monitoring.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Label-Free Optical Metabolic Imaging in Cells and Tissues.Annual review of biomedical engineering · 2023Review
- Advanced Fluorescence Microscopy Methods to Study Dynamics of Fluorescent Proteins In Vivo.Methods in molecular biology (Clifton, N.J.) · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
We describe a method based on a pair of transmission filters placed in the emission path of a microscope to resolve the emission wavelength of every point in an image. The method can be applied to any type of imaging device that provides the light in the wavelength transmission range of the filters. Unique characteristics of the filter approach are that the light does not need to be collimated and the wavelength response does not depend on the scattering of the sample or tissue. The pair of filters are used to produce the spectral phasor of the transmitted light, which is sufficient to perform spectral deconvolution over a broad wavelength range. The method is sensitive enough to distinguish free and protein-bound NADH and can be used in metabolic studies.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.