ArticleThrombosis journal2021
Calibrated automated thrombogram II: removing barriers for thrombin generation measurements.
Article in Thrombosis journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed.
- In silico analysis of patient specific coagulation and flow effects on fibrin clot formation.Scientific reports · 2026Article
- Modelling the effects of 4-factor prothrombin complex concentrate for the management of factor Xa-associated bleeding.PloS one · 2024Article
- How to assess hypercoagulability in heparin-induced thrombocytopenia? Biomarkers of potential value to support therapeutic intensity of non-heparin anticoagulation.Thrombosis journal · 2023Article
- Anticoagulant Activity of Nucleic Acid Nanoparticles (NANPs) Assessed by Thrombin Generation Dynamics on a Fully Automated System.Methods in molecular biology (Clifton, N.J.) · 2023Article
- Hemostasis Disturbances in Continuous-Flow Left Ventricular Assist Device (CF-LVAD) Patients-Rationale and Study Design.Journal of clinical medicine · 2022Article
- Analytical performance of the endogenous thrombin potential-based activated protein C resistance assay on the automated ST Genesia system.Research and practice in thrombosis and haemostasis · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThrombin generation (TG) assessed by Calibrated Automated Thrombogram (CAT-I) reflects the overall capacity of plasma to generate thrombin, thus evaluating the balance between the anti- and procoagulant processes. However, with this method the calibrator curve is usually not measured until completion which has a severe impact on the calculation of the TG parameters, especially under conditions where almost all substrate is consumed. In addition, direct thrombin inhibitor (DTI) cannot be present in the calibration sample due to inhibition of the calibrator. We have developed a modified TG assay (CAT-II) and performed head-to-head comparison with the CAT-I method using the same fluorometer. Furthermore, we have compared our CAT-II method to a new automated TG instrument (ST®-Genesia) using the same calibration method.
methodsTG was assessed with CAT-I and CAT-II using the same fulorometer and with ST®-Genesia in control plasma and plasma containing different anticoagulants (dabigatran, rivaroxaban, apixaban) and plasmas to which common interfering substances, bilirubin, hemoglobin and lipids were added. In CAT-I, calibration was against the same plasma containing calibrator in the presence of fluorogenic substrate (Z-GGR-AMC). In contrast, CAT-II method and ST®-Genesia used a standard concentration of thrombin in buffer and 7-amino-4-methylcoumarin (AMC) in a separate plasma sample for calibration.
resultsTG obtained from CAT-I using anticoagulant-free plasmas was lower compared with TG from CAT-II but both methods demonstrated an intra-assay variation less than 5% on all measured parameters. When comparing the two different calibration methods in the presence of different anticoagulants, a high correlation was seen in the presence of rivaroxaban and apixaban (R
conclusionsOur results showed high similarity between the results of CAT-I and CAT-II method when it is applied in control plasmas and plasmas not inhibited with a direct thrombin inhibitor. Furthermore, both the CAT-II method and ST-Genesia using the same calibration method were able to detect the effect of all oral anticoagulants. Taken together, applying a new calibration method is a significant improvement for monitoring patients on direct thrombin inhibitors while not introducing any bias to results obtained on other types of samples.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.