ArticleAnnals of intensive care2021
Bioreactance reliably detects preload responsiveness by the end-expiratory occlusion test when averaging and refresh times are shortened.
Article in Annals of intensive care, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.
- Context-specific clinical applicability of the end-expiratory occlusion test to predict fluid responsiveness in mechanically ventilated patients: A systematic review and meta-analysis.European journal of anaesthesiology · 2025Pooled it
- Non-Invasive Hemodynamic Monitoring in Critically Ill Patients: A Guide for Emergency Physicians.Journal of clinical medicine · 2025Review
- Does the thoracic fluid content reflect lung water and cardiac preload?Journal of clinical monitoring and computing · 2025Article
- Real-time changes in pulse pressure during a 10-second end-expiratory occlusion test reliably detect preload responsiveness.Critical care (London, England) · 2025Article
- Article
- Testing preload responsiveness by the tidal volume challenge assessed by the photoplethysmographic perfusion index.Critical care (London, England) · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe end-expiratory occlusion (EEXPO) test detects preload responsiveness, but it is 15 s long and induces small changes in cardiac index (CI). It is doubtful whether the Starling bioreactance device, which averages CI over 24 s and refreshes the displayed value every 4 s (Starling-24.4), can detect the EEXPO-induced changes in CI (ΔCI). Our primary goal was to test whether this Starling device version detects preload responsiveness through EEXPO. We also tested whether shortening the averaging and refresh times to 8 s and one second, respectively, (Starling-8.1) improves the accuracy of the device in detecting preload responsiveness using EEXPO.
methodsIn 42 mechanically ventilated patients, during a 15-s EEXPO, we measured ∆CI through calibrated pulse contour analysis (CI
resultsTwenty-six patients were preload responders and sixteen non preload-responders. The AUROC for ∆CI
conclusionsShortening the averaging and refresh times of the bioreactance signal to 8 s and one second, respectively, increases the reliability of the Starling device in detection of EEXPO-induced ∆CI.
trial registrationNo. IDRCB: 2018-A02825-50. Registered 13 December 2018.