Verification of Surface Dose for Flattening Filter and Flattening Filter Free Beams in Beam-Matched Medical Linear Accelerators.

N Sushma, Shanmukhappa Kaginelli, Sathiaraj Palanivel, K M Ganesh

Abstract read
In one paragraph

Article in Asian Pacific journal of cancer prevention : APJCP, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

N SushmaDepartment of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, India.
Shanmukhappa KaginelliDivision of Medical Physics, JSS Academy of Higher Education and Research, Mysuru, India.
Sathiaraj PalanivelDepartment of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, India.
K M GaneshDepartment of Radiation Physics, Kidwai Memorial Institute of Oncology, Bengaluru, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe purpose of this study was to evaluate the surface dose (SD) of 6 and 10 MV flattening filter beam (FF) and flattening filter free (FFF) beam for different square field sizes in three Beam-matched medical linear accelerators using a parallel-plate ionization chamber. MATERIALS AND

methodsThe experiment was carried out in a phantom composed of 40×40 cm2 solid Water slabs of varying thickness. Further sheets of solid water phantom were added to take readings in the build-up region for both SSD and SAD technique. Surface doses are measured with a PPC-05 chamber and DOSE 1 electrometer, at measurement depth of 1 mm interval and all results are plotted relative to the dose measured at Dmax for various field sizes. Surface dose readings are therefore reported as relative surface dose.

resultsSurface dose increased linearly with field size for both FF and FFF photon beams in all three beam-matched linear accelerators in both SSD and SAD setup. The surface dose of FFF was higher than FF beams in all field sizes. For the given energy the surface dose difference (relative to 10x10 cm2 field size of 6FF) between FF and FFF beam was larger for large field size. For 6FF and 6FFF beam the surface dose difference for 5x5 cm2 is -5.27%, and for 30x30 cm2 it is 12.91%. The measured surface dose differences between linear accelerators are not statically significant (P>0.989). Similarly, the surface dose difference between SSD and SAD setup was also analysed and had no statistical significance (P>0.849).

conclusionStudy showed that the surface dose difference between beam-matched linear accelerators are insignificant. The surface dose difference between SSD and SAD setup were also found negligible. Most importantly, changing patients between beam-matched linear accelerators will not have any significant changes in surface dose in clinical setup.<br />.

Indexed as

Phantoms, ImagingFiltrationHumansParticle AcceleratorsRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedParallel Plate Chamberpercentage depth doseSource to Axis DistanceSource to Surface DistanceSurface dose

Identifiers

PMID34452573
PMCPMC8629463

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.