Evidence map›Paper›PMID 34450927›Full record

ArticleSensors (Basel, Switzerland)2021

MAS: Standalone Microwave Resonator to Assess Muscle Quality.

Viktor Mattsson, Leanne L G C Ackermans, Bappaditya Mandal, Mauricio D Perez, Maud A M Vesseur, Paul Meaney, Jan A Ten Bosch, Taco J Blokhuis, Robin Augustine

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. An inkjet-printed bendable antenna for wearable electronics.International journal of bioprinting · 2023
    Article
  3. Article
  4. Article
  5. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 3 countries.

Viktor MattssonÅngström Laboratory, Division of Solid State Electronics, Department of Electrical Engineering, Uppsala University, SE-75121 Uppsala, Sweden.ORCID 0000-0001-8065-0094
Leanne L G C AckermansDepartment of Traumatology, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands.
Bappaditya MandalÅngström Laboratory, Division of Solid State Electronics, Department of Electrical Engineering, Uppsala University, SE-75121 Uppsala, Sweden.ORCID 0000-0002-1092-6216
Mauricio D PerezÅngström Laboratory, Division of Solid State Electronics, Department of Electrical Engineering, Uppsala University, SE-75121 Uppsala, Sweden.ORCID 0000-0003-4821-8087
Maud A M VesseurDepartment of Traumatology, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands.ORCID 0000-0001-9086-9620
Paul MeaneyThayer School of Engineering, Dartmouth College, Hanover, NH 03755, USA.
Jan A Ten BoschDepartment of Traumatology, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands.ORCID 0000-0002-6195-9704
Taco J BlokhuisDepartment of Traumatology, Maastricht University Medical Centre+, 6229 HX Maastricht, The Netherlands.ORCID 0000-0002-3601-3458
Robin AugustineÅngström Laboratory, Division of Solid State Electronics, Department of Electrical Engineering, Uppsala University, SE-75121 Uppsala, Sweden.
Maastricht University Medical Centre · NLUppsala University · SEDartmouth College · US

Funding

Simultaneous Microwave and MR Imaging for Improved Diagnosis of Breast AbnormalitiesR01CA240760 · NCI · DARTMOUTH COLLEGE · PI MEANEY, PAUL M, PAULSEN, KEITH D. · 2020 to 2024
$3.0M
Eurostars E! 114232NCI NIH HHS R01 CA240760
6 · The paper itself

Abstract

Microwave-based sensing for tissue analysis is recently gaining interest due to advantages such as non-ionizing radiation and non-invasiveness. We have developed a set of transmission sensors for microwave-based real-time sensing to quantify muscle mass and quality. In connection, we verified the sensors by 3D simulations, tested them in a laboratory on a homogeneous three-layer tissue model, and collected pilot clinical data in 20 patients and 25 healthy volunteers. This report focuses on initial sensor designs for the Muscle Analyzer System (MAS), their simulation, laboratory trials and clinical trials followed by developing three new sensors and their performance comparison. In the clinical studies, correlation studies were done to compare MAS performance with other clinical standards, specifically the skeletal muscle index, for muscle mass quantification. The results showed limited signal penetration depth for the Split Ring Resonator (SRR) sensor. New sensors were designed incorporating Substrate Integrated Waveguides (SIW) and a bandstop filter to overcome this problem. The sensors were validated through 3D simulations in which they showed increased penetration depth through tissue when compared to the SRR. The second-generation sensors offer higher penetration depth which will improve clinical data collection and validation. The bandstop filter is fabricated and studied in a group of volunteers, showing more reliable data that warrants further continuation of this development.

Indexed as

MicrowavesMusclesComputer SimulationHumansbandstop filtermicrowave sensingmuscle qualitysarcopeniasubstrate integrated waveguides

Identifiers

PMID34450927
PMCPMC8399157
OpenAlexW3196066521

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.