ArticleSensors (Basel, Switzerland)2021
Kinetic Sensors for Ligament Balance and Kinematic Evaluation in Anatomic Bi-Cruciate Stabilized Total Knee Arthroplasty.
Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 16 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
16 citing papers in PubMed, 1 synthesis or guideline pooled it, 23 citations in OpenAlex.
- Sensor-guided gap balance versus manual gap balance in primary total knee arthroplasty: a meta-analysis.Journal of orthopaedic surgery and research · 2022Pooled it
- Effect of Combined Kinematic Chain Exercise on Physical Function, Balance Ability, and Gait in Patients with Total Knee Arthroplasty: A Single-Blind Randomized Controlled Trial.International journal of environmental research and public health · 2023Trial
- Inter- and Intra-Rater Reliability of Pre-Resection Ligament Tension Assessment Using a Digital Tensioner in Imageless Robotic-Assisted Total Knee Replacement.Orthopaedic surgery · 2026Article
- Medial-pivot total knee arthroplasty demonstrates more constrained mid-flexion gait kinematics than posterior-stabilised total knee arthroplasty under standardised soft-tissue balancing: A randomised controlled trial with a healthy reference cohort.Journal of experimental orthopaedics · 2026Article
- Alignment and/or ligament balancing? Towards truly personalized total knee arthroplasty-A narrative review.Journal of experimental orthopaedics · 2026Review
- Artificial intelligence in total knee arthroplasty: clinical applications and implications.Knee surgery & related research · 2025Review
- No significant clinical differences between native or reduced posterior tibial slope in kinematically aligned total knee replacement with posterior cruciate-retaining.Journal of orthopaedics · 2024Article
- No evidence of mid-flexion instability after robotic-assisted total knee arthroplasty as assessed by intraoperative pressure sensors.Arthroplasty (London, England) · 2024Article
- Model Properties and Clinical Application in the Finite Element Analysis of Knee Joint: A Review.Orthopaedic surgery · 2024Review
- SMART (self- monitoring analysis and reporting technology) and sensor based technology applications in trauma and orthopaedic surgery.Journal of orthopaedics · 2023Review
- Comparison between gaits after a medial pivot and posterior stabilized primary total knee arthroplasty: a systematic review of the literature.Arthroplasty (London, England) · 2023Review
- Highly cross-linked polyethylene versus conventional polyethylene in primary total knee arthroplasty: comparable clinical and radiological results at a 10-year follow-up.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Established and Novel Risk Factors for 30-Day Readmission Following Total Knee Arthroplasty: A Modified Delphi and Focus Group Study to Identify Clinically Important Predictors.Journal of clinical medicine · 2023Article
- No Significant Differences in Clinical and Radiographic Outcomes between PCL Retained or Sacrificed Kinematic Aligned Medial Pivot Total Knee Arthroplasty in Varus Knee.Journal of clinical medicine · 2022Article
- Sensors and digital medicine in orthopaedic surgery.OTA international : the open access journal of orthopaedic trauma · 2022Article
- Restricted kinematic alignment in primary total knee arthroplasty: A systematic review of radiographic and clinical data.Journal of orthopaedicsReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Sensor technology was introduced to intraoperatively analyse the differential pressure between the medial and lateral compartments of the knee during primary TKA using a sensor to assess if further balancing procedures are needed to achieve a "balanced" knee. The prognostic role of epidemiological and radiological parameters was also analysed. A consecutive series of 21 patients with primary knee osteoarthritis were enrolled and programmed for TKA in our unit between 1 September 2020 and 31 March 2021. The VERASENSE Knee System (OrthoSensor Inc., Dania Beach, FL, USA) has been proposed as an instrument that quantifies the differential pressure between the compartments of the knee intraoperatively throughout the full range of motion during primary TKA, designed with a J-curve anatomical femoral design and a PS "medially congruent" polyethylene insert. Thirteen patients (61.90%) showed a "balanced" knee, and eight patients (38.10%) showed an intra-operative "unbalanced" knee and required additional procedures. A total of 13 additional balancing procedures were performed. At the end of surgical knee procedures, a quantitatively balanced knee was obtained in all patients. In addition, a correlation was found between the compartment pressure of phase I and phase II at 10° of flexion and higher absolute pressures were found in the medial compartment than in the lateral compartment in each ROM degree investigated. Moreover, those pressure values showed a trend to decrease with the increase in flexion degrees in both compartments. The "Kinetic Tracking" function displays the knee's dynamic motion through the full ROM to evaluate joint kinetics. The obtained kinetic traces reproduced the knee's medial pivot and femoral rollback, mimicking natural knee biomechanics. Moreover, we reported a statistically significant correlation between the need for soft tissue or bone resection rebalancing and severity of the initial coronal deformity (>10°) and a preoperative JLCA value >2°. The use of quantitative sensor-guided pressure evaluation during TKA leads to a more reproducible "balanced" knee. The surgeon, evaluating radiological parameters before surgery, may anticipate difficulties in knee balance and require those devices to achieve the desired result objectively.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.