Evidence map›Paper›PMID 34450769›Full record

ArticleSensors (Basel, Switzerland)2021

Classification of Bladder Emptying Patterns by LSTM Neural Network Trained Using Acoustic Signatures.

Jie Jin, Youngbeen Chung, Wanseung Kim, Yonggi Heo, Jinyong Jeon, Jeongkyu Hoh, Junhong Park, Jungki Jo

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.5field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 15 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. The Use of Uroflowmetry as a Diagnostic Test.Current urology reports · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Jie JinSchool of Electromechanical and Automotive Engineering, Yantai University, 30 Qingquan Road, Laishan District, Yantai 264005, China.
Youngbeen ChungDepartment of Mechanical Engineering, Hanyang University, Wangsimni-ro 222, Seongdong-Gu, Seoul 04763, Korea.
Wanseung KimDepartment of Mechanical Engineering, Hanyang University, Wangsimni-ro 222, Seongdong-Gu, Seoul 04763, Korea.
Yonggi HeoDepartment of Medical and Digital Engineering, Hanyang University, Wangsimni-ro 222, Seongdong-Gu, Seoul 04763, Korea.
Jinyong JeonDepartment of Architectural Engineering, Hanyang University, Wangsimni-ro 222, Seongdong-Gu, Seoul 04763, Korea.ORCID 0000-0002-1469-4520
Jeongkyu HohDepartment of Obstetrics and Gynecology, Hanyang University Seoul Hospital, Wangsimni-ro 222, Seongdong-Gu, Seoul 04763, Korea.
Junhong ParkDepartment of Mechanical Engineering, Hanyang University, Wangsimni-ro 222, Seongdong-Gu, Seoul 04763, Korea.ORCID 0000-0002-5628-3025
Jungki JoDepartment of Urology, Hanyang University Seoul Hospital, Wangsimni-ro 222, Seongdong-Gu, Seoul 04763, Korea.
Hanyang University · KRHanyang University Seoul Hospital · KRYantai University · CN

Funding

Bio & Medical Technology Development Program of the National Research Foundation (NRF), Korean Government (MSIT) 2019M3E5D1A01069363
6 · The paper itself

Abstract

(1) Background: Non-invasive uroflowmetry is used in clinical practice for diagnosing lower urinary tract symptoms (LUTS) and the health status of a patient. To establish a smart system for measuring the flowrate during urination without any temporospatial constraints for patients with a urinary disorder, the acoustic signatures from the uroflow of patients being treated for LUTS at a tertiary hospital were utilized. (2) Methods: Uroflowmetry data were collected for construction and verification of a long short-term memory (LSTM) deep-learning algorithm. The initial sample size comprised 34 patients; 27 patients were included in the final analysis. Uroflow sounds generated from flow impacts on a structure were analyzed by loudness and roughness parameters. (3) Results: A similar signal pattern to the clinical urological measurements was observed and applied for health diagnosis. (4) Conclusions: Consistent flowrate values were obtained by applying the uroflow sound samples from the randomly selected patients to the constructed model for validation. The flowrate predicted using the acoustic signature accurately demonstrated actual physical characteristics. This could be used for developing a new smart flowmetry device applicable in everyday life with minimal constraints from settings and enable remote diagnosis of urinary system diseases by objective continuous measurements of bladder emptying function.

Indexed as

Urinary BladderUrodynamicsAcousticsHumansNeural Networks, ComputerUrinationacoustic signalclassificationflowrate predictionlong short-term memorylower urinary tract symptoms

Identifiers

PMID34450769
PMCPMC8400043
OpenAlexW3191901227

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.