Evidence map›Paper›PMID 34443967›Full record

ArticleNanomaterials (Basel, Switzerland)2021

Double-Antibody Sandwich Immunoassay and Plasmonic Coupling Synergistically Improved Long-Range SPR Biosensor with Low Detection Limit.

Jianying Jing, Kun Liu, Junfeng Jiang, Tianhua Xu, Shuang Wang, Jinying Ma, Zhao Zhang, Wenlin Zhang, Tiegen Liu

Open access · goldAbstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.8field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 11 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Jianying JingSchool of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.ORCID 0000-0001-7187-2605
Kun LiuSchool of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.ORCID 0000-0003-2460-6851
Junfeng JiangSchool of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Tianhua XuSchool of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Shuang WangSchool of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Jinying MaSchool of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Zhao ZhangSchool of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.ORCID 0000-0002-0941-2031
Wenlin ZhangSchool of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Tiegen LiuSchool of Precision Instruments and Opto-Electronics Engineering, Tianjin University, Tianjin 300072, China.
Tianjin University · CN

Funding

National Instrument Program of China 2013YQ030915National Natural Science Foundation of China 61922061, 61775161 and 61735011Science Fund for Distinguished Young Scholars of Tianjin 19JCJQJC61400
6 · The paper itself

Abstract

A long-range surface plasmonic resonance (LR-SPR) biosensor modified with double-antibody sandwich immunoassay and plasmonic coupling is demonstrated for human-immunoglobulin G detection with a low limit of detection (LOD). The double-antibody sandwich immunoassay dramatically changes the average refractive index of the medium layer on the sensor surface. The near-field electron coupling between the localized surface plasmon and the long-range surface plasmon leads to a significant perturbation of the evanescent field. The large penetration depth and the long propagation distance of the long-range surface plasmonic waves facilitate the LR-SPR sensor in the detection of biological macromolecules. The unique light absorption characteristic of the nanocomposite material in the sensor provides the in situ self-compensation for the disturbance. Therefore, besides the inherent advantages of optical fiber sensors, the developed biosensor can realize the detection of biomolecules with high sensitivity, low LOD and high accuracy and reliability. Experimental results demonstrate that the LOD of the biosensor is as low as 0.11 μg/mL in the detection of the phosphate-buffered saline sample, and the spike-and-repetition rate is 105.56% in the detection of the real serum sample, which partly shows the practicability of the biosensor. This indicates that the LR-SPR biosensor provides better response compared with existing similar sensors and can be regarded as a valuable method for biochemical analysis and disease detection.

Indexed as

double-antibody sandwich immunoassaylow limit of detectionnanocomposite materialnanophotonicsplasmonic coupling between nano goldplasmonic detection

Identifiers

PMID34443967
PMCPMC8400597
OpenAlexW3196273494

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.