Evidence map›Paper›PMID 34443746›Full record

ArticleNanomaterials (Basel, Switzerland)2021

A Full-Range Flexible and Printed Humidity Sensor Based on a Solution-Processed P(VDF-TrFE)/Graphene-Flower Composite.

Shenawar Ali Khan, Muhammad Saqib, Muhammad Muqeet Rehman, Hafiz Mohammad Mutee Ur Rehman, Sheik Abdur Rahman, Yunsook Yang, Seongwan Kim, Woo-Young Kim

Open access · goldAbstract read
In one paragraph

Article in Nanomaterials (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 34 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Shenawar Ali KhanDepartment of Electronic Engineering, Jeju National University, 102 Jejudaehakro, Jeju 63243, Korea.
Muhammad SaqibDepartment of Electronic Engineering, Jeju National University, 102 Jejudaehakro, Jeju 63243, Korea.
Muhammad Muqeet RehmanDepartment of Electronic Engineering, Jeju National University, 102 Jejudaehakro, Jeju 63243, Korea.ORCID 0000-0003-4712-6404
Hafiz Mohammad Mutee Ur RehmanDepartment of Electronic Engineering, Jeju National University, 102 Jejudaehakro, Jeju 63243, Korea.
Sheik Abdur RahmanDepartment of Electronic Engineering, Jeju National University, 102 Jejudaehakro, Jeju 63243, Korea.
Yunsook YangDepartment of Electronic Engineering, Jeju National University, 102 Jejudaehakro, Jeju 63243, Korea.
Seongwan KimDepartment of Electronic Engineering, Jeju National University, 102 Jejudaehakro, Jeju 63243, Korea.
Woo-Young KimDepartment of Electronic Engineering, Jeju National University, 102 Jejudaehakro, Jeju 63243, Korea.ORCID 0000-0003-2747-6618
Jeju National University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A novel composite based on a polymer (P(VDF-TrFE)) and a two-dimensional material (graphene flower) was proposed as the active layer of an interdigitated electrode (IDEs) based humidity sensor. Silver (Ag) IDEs were screen printed on a flexible polyethylene terephthalate (PET) substrate followed by spin coating the active layer of P(VDF-TrFE)/graphene flower on its surface. It was observed that this sensor responds to a wide relative humidity range (RH%) of 8-98% with a fast response and recovery time of 0.8 s and 2.5 s for the capacitance, respectively. The fabricated sensor displayed an inversely proportional response between capacitance and RH%, while a directly proportional relationship was observed between its impedance and RH%. P(VDF-TrFE)/graphene flower-based flexible humidity sensor exhibited high sensitivity with an average change of capacitance as 0.0558 pF/RH%. Stability of obtained results was monitored for two weeks without any considerable change in the original values, signifying its high reliability. Various chemical, morphological, and electrical characterizations were performed to comprehensively study the humidity-sensing behavior of this advanced composite. The fabricated sensor was successfully used for the applications of health monitoring and measuring the water content in the environment.

Indexed as

flexiblehealth monitoringhumidity sensorP(VDF-TrFE)/graphene flower compositesolution processed

Identifiers

PMID34443746
PMCPMC8398072
OpenAlexW3185138497

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.