Evidence map›Paper›PMID 34443348›Full record

ReviewMolecules (Basel, Switzerland)2021

Moving toward a Handheld "Plasma" Spectrometer for Elemental Analysis, Putting the Power of the Atom (Ion) in the Palm of Your Hand.

Brian T Buckley, Rachel Buckley, Cathleen L Doherty

Open access · goldAbstract readReview
In one paragraph

Review in Molecules (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 5 citations in OpenAlex.

  1. Fundamental characteristics of voltage-modulated helium plasma for multi-element analysis in low-volume samples.Analytical sciences : the international journal of the Japan Society for Analytical Chemistry · 2026
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Brian T BuckleyEnvironmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ 08854, USA.
Rachel BuckleyDepartment of Chemistry, Indiana University, Bloomington, IN 47405, USA.
Cathleen L DohertyEnvironmental and Occupational Health Sciences Institute, Rutgers University, Piscataway, NJ 08854, USA.ORCID 0000-0001-8831-6330
Rutgers, The State University of New Jersey · USIndiana University Bloomington · US

Funding

NIEHS NIH HHS ES05022
6 · The paper itself

Abstract

Many of the current innovations in instrument design have been focused on making them smaller, more rugged, and eventually field transportable. The ultimate application is obvious, carrying the instrument to the field for real time sample analysis without the need for a support laboratory. Real time data are priceless when screening either biological or environmental samples, as mitigation strategies can be initiated immediately upon the discovery that contaminant metals are present in a location they were not intended to be. Additionally, smaller "handheld" instruments generally require less sample for analysis, possibly increasing sensitivity, another advantage to instrument miniaturization. While many other instruments can be made smaller just by using available micro-technologies (e.g., eNose), shrinking an ICP-MS or AES to something someone might carry in a backpack or pocket is now closer to reality than in the past, and can be traced to its origins based on a component-by-component evaluation. While the optical and mass spectrometers continue to shrink in size, the ion/excitation source remains a challenge as a tradeoff exists between excitation capabilities and the power requirements for the plasma's generation. Other supporting elements have only recently become small enough for transport. A systematic review of both where the plasma spectrometer started and the evolution of technologies currently available may provide the roadmap necessary to miniaturize the spectrometer. We identify criteria on a component-by-component basis that need to be addressed in designing a miniaturized device and recognize components (e.g., source) that probably require further optimization. For example, the excitation/ionization source must be energetic enough to take a metal from a solid state to its ionic state. Previously, a plasma required a radio frequency generator or high-power DC source, but excitation can now be accomplished with non-thermal (cold) plasma sources. Sample introduction, for solids, liquids, and gasses, presents challenges for all sources in a field instrument. Next, the interface between source and a mass detector usually requires pressure reduction techniques to get an ion from plasma to the spectrometer. Currently, plasma mass spectrometers are field ready but not necessarily handheld. Optical emission spectrometers are already capable of getting photons to the detector but could eventually be connected to your phone. Inert plasma gas generation is close to field ready if nitrogen generators can be miniaturized. Many of these components are already commercially available or at least have been reported in the literature. Comparisons to other "handheld" elemental analysis devices that employ XRF, LIBS, and electrochemical methods (and their limitations) demonstrate that a "cold" plasma-based spectrometer can be more than competitive. Migrating the cold plasma from an emission only source to a mass spectrometer source, would allow both analyte identification and potentially source apportionment through isotopic fingerprinting, and may be the last major hurdle to overcome. Finally, we offer a possible design to aid in making the cold plasma source more applicable to a field deployment.

Indexed as

excitationhandheld device designionizationmetal analytesmicro-technologyplasmaspectrometer

Identifiers

PMID34443348
PMCPMC8400342
OpenAlexW3190848447

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.