Evidence map›Paper›PMID 34442407›Full record

ArticleJournal of personalized medicine2021

Accuracy of Patient-Specific Drilling Guides in Acetabular Fracture Surgery: A Human Cadaver Study.

Anne M L Meesters, Nick Assink, Kaj Ten Duis, Eelco M Fennema, Joep Kraeima, Max J H Witjes, Jean-Paul P M de Vries, Vincent M A Stirler, Frank F A IJpma

Open access · goldAbstract read
In one paragraph

Article in Journal of personalized medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 11 citations in OpenAlex.

  1. Article
  2. Navigation and intraoperative imaging in pelvic and acetabular trauma.OTA international : the open access journal of orthopaedic trauma · 2025
    Article
  3. Review
  4. Development of patient-specific osteosynthesis including 3D-printed drilling guides for medial tibial plateau fracture surgery.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
  5. 3D-assisted corrective osteotomies of the distal radius: a comparison of pre-contoured conventional implants versus patient-specific implants.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2024
    Article
  6. Article
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Anne M L MeestersDepartment of Surgery, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.ORCID 0000-0001-6882-0054
Nick AssinkDepartment of Surgery, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
Kaj Ten DuisDepartment of Surgery, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
Eelco M FennemaDepartment of Surgery, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
Joep Kraeima3D Lab, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
Max J H Witjes3D Lab, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
Jean-Paul P M de VriesDepartment of Surgery, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
Vincent M A StirlerDepartment of Surgery, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.ORCID 0000-0003-0745-0074
Frank F A IJpmaDepartment of Surgery, University Medical Centre Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands.
University Medical Center Groningen · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Due to the complex anatomical shape of the pelvis, screw placement can be challenging in acetabular fracture surgery. This study aims to assess the accuracy of screw placement using patient-specific surgical drilling guides applied to pre-contoured conventional implants in acetabular fracture surgery. CT scans were made of four human cadavers to create 3D models of each (unfractured) pelvis. Implants were pre-contoured on 3D printed pelvic models and optically scanned. Following virtual preoperative planning, surgical drilling guides were designed to fit on top of the implant and were 3D printed. The differences between the pre-planned and actual screw directions (degrees) and screw entry points (mm) were assessed from the pre- and postoperative CT-scans. The median difference between the planned and actual screw direction was 5.9° (IQR: 4-8°) for the in-plate screws and 7.6° (IQR: 6-10°) for the infra-acetabular and column screws. The median entry point differences were 3.6 (IQR: 2-5) mm for the in-plate screws and 2.6 (IQR: 2-3) mm for the infra-acetabular and column screws. No screws penetrated into the hip joint or caused soft tissue injuries. Three-dimensional preoperative planning in combination with surgical guides that envelope pre-contoured conventional implants result in accurate screw placement during acetabular fracture surgery.

Indexed as

3D print3D virtual surgical planningacetabular fracturepatient-specificsurgical guides

Identifiers

PMID34442407
PMCPMC8400721
OpenAlexW3189811581

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.