Evidence map›Paper›PMID 34441366›Full record

ArticleDiagnostics (Basel, Switzerland)2021

Diagnostic Performance of Electromagnetic Navigation Bronchoscopy-Guided Biopsy for Lung Nodules in the Era of Molecular Testing.

Ju Hyun Oh, Chang-Min Choi, Seulgi Kim, Se Jin Jang, Sang Young Oh, Mi Young Kim, Hee Sang Hwang, Wonjun Ji

Abstract read
In one paragraph

Article in Diagnostics (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Review
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ju Hyun OhAsan Medical Center, Department of Pulmonary and Critical Care Medicine, University of Ulsan College of Medicine, Seoul 05505, Korea.ORCID 0000-0003-0756-3810
Chang-Min ChoiAsan Medical Center, Department of Pulmonary and Critical Care Medicine, University of Ulsan College of Medicine, Seoul 05505, Korea.
Seulgi KimAsan Medical Center, Department of Pulmonary and Critical Care Medicine, University of Ulsan College of Medicine, Seoul 05505, Korea.
Se Jin JangAsan Medical Center, Department of Pathology, University of Ulsan College of Medicine, Seoul 05505, Korea.
Sang Young OhAsan Medical Center, Department of Radiology, University of Ulsan College of Medicine, Seoul 05505, Korea.
Mi Young KimAsan Medical Center, Department of Radiology, University of Ulsan College of Medicine, Seoul 05505, Korea.
Hee Sang HwangAsan Medical Center, Department of Pathology, University of Ulsan College of Medicine, Seoul 05505, Korea.
Wonjun JiAsan Medical Center, Department of Pulmonary and Critical Care Medicine, University of Ulsan College of Medicine, Seoul 05505, Korea.ORCID 0000-0001-7164-2770

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Electromagnetic navigation bronchoscopy (ENB) is an emerging technique used to evaluate peripheral lung lesions. The aim of this study was to determine the diagnostic yield, safety profile, and adequacy of specimens obtained using ENB for molecular testing. This single-center, prospective pilot study recruited patients with peripheral pulmonary nodules that were not suitable for biopsy via percutaneous transthoracic needle biopsy methods. The possibility of molecular testing, including epidermal growth factor receptor (EGFR), anaplastic lymphoma kinase (ALK), and programmed death ligand 1 (PD-L1), was identified with non-small cell lung cancer (NSCLC) tissue obtained using ENB. ENB-guided biopsy was performed on 30 pulmonary nodules in 30 patients. ENB-guided biopsy was successfully performed in 96.6% (29/30) of cases, but one case failed to approach the target lesion. The diagnostic accuracy of ENB-guided biopsy was 68.0% (17/25). Biopsy-related pneumothorax occurred in one patient and there was no major bleeding or deaths related to the procedure. Among 13 patients diagnosed with NSCLC, molecular testing was successfully performed in 92.3% (12/13). ENB-guided biopsy demonstrated acceptable accuracy and excellent sample adequacy, with a high possibility of achieving molecular testing and a good safety profile to evaluate peripheral pulmonary nodules, even when the percutaneous approach was difficult and/or dangerous.

Indexed as

accuracydiagnostic yieldelectromagnetic navigation bronchoscopylung nodulesafety

Identifiers

PMID34441366
PMCPMC8393972

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.