ArticleChildren (Basel, Switzerland)2021
Newborn Incubators Do Not Protect from High Noise Levels in the Neonatal Intensive Care Unit and Are Relevant Noise Sources by Themselves.
Article in Children (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05711927 (The Effect of Sleeping Environment on Sleep-Wake Organization in Preterm Infants), which is not on this map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Effect of Sleeping Environment on Sleep-Wake Organization in Preterm Infants
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 28 citations in OpenAlex.
- Risk Factors for Hearing Loss Are Comparable in Preterm Versus Term Children: A Systematic Review.Acta paediatrica (Oslo, Norway : 1992) · 2025Pooled it
- Music-based research in neonatal intensive care units requires guidelines grounded in developmental neurology and responsive to the individual needs of preterm infants.Frontiers in psychology · 2026Article
- What's that noise-tackling sound pollution in the NICU: a systematic review.Frontiers in pediatrics · 2026Review
- Exploring the sound environment in neonatal intensive care units as perceived by medical professionals.Fujita medical journal · 2025Article
- Neonatal Nurses' Perceptions and Objective Indices of Noise During Quiet Hours in the NICU.Advances in neonatal care : official journal of the National Association of Neonatal Nurses · 2025Observational
- Noise prevention strategies among neonatal intensive care unit nurses: a qualitative study.BMC nursing · 2025Article
- Article
- Creative music therapy in preterm infants effects cerebrovascular oxygenation and perfusion.Scientific reports · 2024Article
- Noise Produced by Various Respiratory Support Techniques During Neonatal Transportation: A Simulation Study.Respiratory care · 2024Article
- Home Musical Activities Boost Premature Infants' Language Development.Children (Basel, Switzerland) · 2024Article
- Analysis of noise levels in the neonatal intensive care unit: the impact of clinical microsystems.European journal of pediatrics · 2024Article
- Noise Produced by Neonatal Ventilators Inside and Outside of the Incubators.Respiratory care · 2023Article
- Neonatal warming devices: What can be recommended for low-resource settings when skin-to-skin care is not feasible?Frontiers in pediatrics · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundWhile meaningful sound exposure has been shown to be important for newborn development, an excess of noise can delay the proper development of the auditory cortex.
aimThe aim of this study was to assess the acoustic environment of a preterm baby in an incubator on a newborn intensive care unit (NICU).
methodsAn empty but running incubator (Giraffe Omnibed, GE Healthcare) was used to evaluate the incubator frequency response with 60 measurements. In addition, a full day and night period outside and inside the incubator at the NICU of the University Hospital Zurich was acoustically analyzed.
resultsThe fan construction inside the incubator generates noise in the frequency range of 1.3-1.5 kHz with a weighted sound pressure level (SPL) of 40.5 dB(A). The construction of the incubator narrows the transmitted frequency spectrum of sound entering the incubator to lower frequencies, but it does not attenuate transient noises such as alarms or opening and closing of cabinet doors substantially. Alarms, as generated by the monitors, the incubator, and additional devices, still pass to the newborn.
conclusionsThe incubator does protect only insufficiently from noise coming from the NICUThe transmitted frequency spectrum is changed, limiting the impact of NICU noise on the neonate, but also limiting the neonate's perception of voices. The incubator, in particular its fan, as well as alarms from patient monitors are major sources of noise. Further optimizations with regard to the sound exposure in the NICU, as well as studies on the role of the incubator as a source and modulator, are needed to meet the preterm infants' multi-sensory needs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.