Newborn Incubators Do Not Protect from High Noise Levels in the Neonatal Intensive Care Unit and Are Relevant Noise Sources by Themselves.

Tanja Restin, Mikael Gaspar, Dirk Bassler, Vartan Kurtcuoglu, Felix Scholkmann, Friederike Barbara Haslbeck

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Children (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05711927 (The Effect of Sleeping Environment on Sleep-Wake Organization in Preterm Infants), which is not on this map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
7.7field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05711927 nacompletednot on this mapstarted 2023, after this paper: background citation

The Effect of Sleeping Environment on Sleep-Wake Organization in Preterm Infants

TypeinterventionalSponsorColumbia UniversityRan2023 to 2025Enrolled20ConditionsPrematurity, Very Preterm Maturity of InfantArmsSNOO Smart Sleeper, Traditional bassinet
3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it, 28 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Neonatal Nurses' Perceptions and Objective Indices of Noise During Quiet Hours in the NICU.Advances in neonatal care : official journal of the National Association of Neonatal Nurses · 2025
    Observational
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Tanja RestinDepartment of Neonatology, Newborn Research Zurich, University Hospital Zurich, 8091 Zurich, Switzerland.ORCID 0000-0002-8816-6069
Mikael GasparInstitute of Physiology, University of Zurich, 8057 Zurich, Switzerland.
Dirk BasslerDepartment of Neonatology, Newborn Research Zurich, University Hospital Zurich, 8091 Zurich, Switzerland.
Vartan KurtcuogluInstitute of Physiology, University of Zurich, 8057 Zurich, Switzerland.
Felix ScholkmannDepartment of Neonatology, Newborn Research Zurich, University Hospital Zurich, 8091 Zurich, Switzerland.ORCID 0000-0002-1748-4852
Friederike Barbara HaslbeckDepartment of Neonatology, Newborn Research Zurich, University Hospital Zurich, 8091 Zurich, Switzerland.ORCID 0000-0002-4076-8028
University Hospital of Zurich · CHUniversity of Zurich · CH

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWhile meaningful sound exposure has been shown to be important for newborn development, an excess of noise can delay the proper development of the auditory cortex.

aimThe aim of this study was to assess the acoustic environment of a preterm baby in an incubator on a newborn intensive care unit (NICU).

methodsAn empty but running incubator (Giraffe Omnibed, GE Healthcare) was used to evaluate the incubator frequency response with 60 measurements. In addition, a full day and night period outside and inside the incubator at the NICU of the University Hospital Zurich was acoustically analyzed.

resultsThe fan construction inside the incubator generates noise in the frequency range of 1.3-1.5 kHz with a weighted sound pressure level (SPL) of 40.5 dB(A). The construction of the incubator narrows the transmitted frequency spectrum of sound entering the incubator to lower frequencies, but it does not attenuate transient noises such as alarms or opening and closing of cabinet doors substantially. Alarms, as generated by the monitors, the incubator, and additional devices, still pass to the newborn.

conclusionsThe incubator does protect only insufficiently from noise coming from the NICUThe transmitted frequency spectrum is changed, limiting the impact of NICU noise on the neonate, but also limiting the neonate's perception of voices. The incubator, in particular its fan, as well as alarms from patient monitors are major sources of noise. Further optimizations with regard to the sound exposure in the NICU, as well as studies on the role of the incubator as a source and modulator, are needed to meet the preterm infants' multi-sensory needs.