Evidence map›Paper›PMID 34432901›Full record

ArticleMedical physics2021

Harmonization of in-plane resolution in CT using multiple reconstructions from single acquisitions.

Gonzalo Vegas-Sánchez-Ferrero, Gabriel Ramos-Llordén, Raúl San José Estépar

Open access · greenAbstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 85% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

Gonzalo Vegas-Sánchez-FerreroApplied ChestImaging Laboratory (ACIL), Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
Gabriel Ramos-LlordénDepartment of Radiology, Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.
Raúl San José EstéparApplied ChestImaging Laboratory (ACIL), Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
Brigham and Women's Hospital · USHarvard University · USMassachusetts General Hospital · US

Funding

The American Lung Association (ALA) Lung Health CohortU01HL146408 · NHLBI · NORTHWESTERN UNIVERSITY AT CHICAGO · PI CARNETHON, MERCEDES RENEE, KALHAN, RAVI · 2019 to 2024
$25.2M
The clinical impact of pulmonary vascular remodeling in smokersR01HL116473 · NHLBI · BRIGHAM AND WOMEN'S HOSPITAL · PI SAN JOSE ESTEPAR, RAUL, WASHKO, GEORGE R · 2013 to 2021
$5.0M
Prognostic Markers of Emphysema ProgressionR01HL149877 · NHLBI · BRIGHAM AND WOMEN'S HOSPITAL · PI SAN JOSE ESTEPAR, RAUL · 2020 to 2023
$2.8M
Statistical Standardization of CT for the Analysis of Parenchymal Injury Progression in SmokersK25HL143278 · NHLBI · BRIGHAM AND WOMEN'S HOSPITAL · PI VEGAS SANCHEZ-FERRERO, GONZALO · 2019 to 2023
$935k
Robust Detection of Early Small Airway DiseaseR21HL156229 · NHLBI · BRIGHAM AND WOMEN'S HOSPITAL · PI VEGAS SANCHEZ-FERRERO, GONZALO · 2021 to 2022
$269k
CT-based Predictors of ILA Progression in COPDGeneR21HL140422 · NHLBI · BRIGHAM AND WOMEN'S HOSPITAL · PI SAN JOSE ESTEPAR, RAUL · 2017 to 2018
$264k
Boehringer IngelheimNHLBI NIH HHS K25 HL143278NHLBI NIH HHS K25HL143278NHLBI NIH HHS R01 HL116473NHLBI NIH HHS R01HL116473NHLBI NIH HHS R01 HL149877NHLBI NIH HHS R01HL149877NHLBI NIH HHS R21 HL140422NHLBI NIH HHS R21 HL156229NHLBI NIH HHS R21HL156229NHLBI NIH HHS U01 HL146408NHLBI NIH HHS U01HL146408
6 · The paper itself

Abstract

purposeTo providea methodology that removes the spatial variability of in-plane resolution using different CT reconstructions. The methodology does not require any training, sinogram, or specific reconstruction method.

methodsThe methodology is formulated as a reconstruction problem. The desired sharp image is modeled as an unobservable variable to be estimated from an arbitrary number of observations with spatially variant resolution. The methodology comprises three steps: (1) density harmonization, which removes the density variability across reconstructions; (2) point spread function (PSF) estimation, which estimates a spatially variant PSF with arbitrary shape; (3) deconvolution, which is formulated as a regularized least squares problem. The assessment was performed with CT scans of phantoms acquired with three different Siemens scanners (Definition AS, Definition AS+, Drive). Four low-dose acquisitions reconstructed with backprojection and iterative methods were used for the resolution harmonization. A sharp, high-dose (HD) reconstruction was used as a validation reference. The different factors affecting the in-plane resolution (radial, angular, and longitudinal) were studied with regression analysis of the edge decay (between 10% and 90% of the edge spread function (ESF) amplitude).

resultsResults showed that the in-plane resolution improves remarkably and the spatial variability is substantially reduced without compromising the noise characteristics. The modulated transfer function (MTF) also confirmed a pronounced increase in resolution. The resolution improvement was also tested by measuring the wall thickness of tubes simulating airways. In all scanners, the resolution harmonization obtained better performance than the HD, sharp reconstruction used as a reference (up to 50 percentage points). The methodology was also evaluated in clinical scans achieving a noise reduction and a clear improvement in thin-layered structures. The estimated ESF and MTF confirmed the resolution improvement.

conclusionWe propose a versatile methodology to reduce the spatial variability of in-plane resolution in CT scans by leveraging different reconstructions available in clinical studies. The methodology does not require any sinogram, training, or specific reconstruction, and it is not limited to a fixed number of input images. Therefore, it can be easily adopted in multicenter studies and clinical practice. The results obtained with our resolution harmonization methodology evidence its suitability to reduce the spatially variant in-plane resolution in clinical CT scans without compromising the reconstruction's noise characteristics. We believe that the resolution increase achieved by our methodology may contribute in more accurate and reliable measurements of small structures such as vasculature, airways, and wall thickness.

Indexed as

Image Processing, Computer-AssistedTomography, X-Ray ComputedAlgorithmsLeast-Squares AnalysisPhantoms, ImagingCT scansdeconvolutionin-plane resolutionreconstruction

Identifiers

PMID34432901
PMCPMC8710308
OpenAlexW3194085382

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.