Evidence map›Paper›PMID 34432182›Full record

ArticleMedical & biological engineering & computing2021

A signal quality assessment-based ECG waveform delineation method used for wearable monitoring systems.

Jialing Xie, Li Peng, Liang Wei, Yushun Gong, Feng Zuo, Juan Wang, Changlin Yin, Yongqin Li

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
2.0field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 19 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Jialing XieDepartment of Biomedical Engineering and Imaging Medicine, Army Medical University, 30 Gaotanyan Main Street, Chongqing, 400038, China.
Li PengDepartment of Biomedical Engineering and Imaging Medicine, Army Medical University, 30 Gaotanyan Main Street, Chongqing, 400038, China.
Liang WeiDepartment of Biomedical Engineering and Imaging Medicine, Army Medical University, 30 Gaotanyan Main Street, Chongqing, 400038, China.
Yushun GongDepartment of Biomedical Engineering and Imaging Medicine, Army Medical University, 30 Gaotanyan Main Street, Chongqing, 400038, China.
Feng ZuoDepartment of Information Technology, Southwest Hospital, Army Medical University, Chongqing, 400038, China.
Juan WangDepartment of Emergency, Southwest Hospital, Army Medical University, Chongqing, 400038, China.
Changlin YinDepartment of Critical Care Medicine, Southwest Hospital, Army Medical University, Chongqing, 400038, China.
Yongqin LiDepartment of Biomedical Engineering and Imaging Medicine, Army Medical University, 30 Gaotanyan Main Street, Chongqing, 400038, China. lyq@tmmu.edu.cn.ORCID http://orcid.org/0000-0002-6114-2382
Army Medical University · CN

Funding

National Natural Science Foundation of China 31771070Natural Science Foundation Project of Chongqing, Chongqing Science and Technology Commission cstc2017jcyjBX0053
6 · The paper itself

Abstract

Identifying transient and nonpersistent abnormal electrocardiogram (ECG) waveforms by continuously monitoring the high-risk populations is of great importance for the diagnosis, treatment, and prevention of cardiovascular diseases. In recent years, fabric electrodes have been widely used in wearable devices because of their non-irritating properties and better comfort than traditional AgCl electrodes. However, the motion noise caused by the relative movement between the fabric electrodes and skin affects the quality of ECGs and reduces the accuracy of diagnosis. Therefore, delineating the ECG waveforms that are recorded from wearable devices with varying levels of noise is still challenging. In this study, a signal quality assessment (SQA)-based ECG waveform delineation method that is used for wearable systems was developed. The ECG signal was first preprocessed by a bandpass filter. Five indices, including the multiscale nonlinear amplitude statistical distribution (adSQI

Indexed as

ElectrocardiographyHeart RateWearable Electronic DevicesAlgorithmsArrhythmias, CardiacHumansSignal Processing, Computer-AssistedECG waveform delineationElectrocardiographySignal quality assessmentSignal quality indices

Identifiers

PMID34432182
OpenAlexW3196013404

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.