SynthesisKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2023
No significant difference in early clinical outcomes of custom versus off-the-shelf total knee arthroplasty: a systematic review and meta-analysis.
Synthesis in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 19 citations in OpenAlex.
- [The importance of individual knee arthroplasty].Orthopadie (Heidelberg, Germany) · 2025Article
- [Technological Innovation in Total Knee Arthroplasty: Navigation, Robotics, and Customization].Revista brasileira de ortopedia · 2025Article
- Technological Innovation in Total Knee Arthroplasty: Navigation, Robotics, and Customization.Revista brasileira de ortopedia · 2025Article
- No clinical relevant differences in early clinical outcomes, patient satisfaction and objective gait and posture analysis between a custom versus off-the-shelf total knee arthroplasty: a prospective controlled study.Archives of orthopaedic and trauma surgery · 2025Article
- Satisfaction after total knee arthroplasty: a prospective matched-pair analysis of patients with customised individually made and off-the-shelf implants.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2023Article
- Improved Knee Function with Customized vs. Off-the-Shelf TKA Implants-Results of a Single-Surgeon, Single-Center, Single-Blinded Study.Journal of personalized medicine · 2023Article
- Patient Specific Instruments and Patient Individual Implants-A Narrative Review.Journal of personalized medicine · 2023Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 5 institutions in 5 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeThe purpose of this systematic review and meta-analysis was to collect, synthesise and critically appraise findings of clinical studies that report outcomes of custom total knee arthroplasty (TKA). The hypothesis was that, compared to off-the-shelf (OTS) TKA, custom TKA would yield better surgical, clinical and radiographic outcomes.
methodsThis systematic review and meta-analysis was performed in accordance with the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA). On 8 February 2021, two authors independently searched and screened articles using MEDLINE®, Embase® and the Cochrane Library without restriction on date of publication. Findings from eligible articles were narratively synthesised and tabulated, and when ≥ 3 comparative studies reported the same outcome, results were pooled and summarised in forest plots. Quality assessments of the studies were done according to the guidelines of the Joanna Briggs Institute (JBI) Checklists.
resultsA total of 15 articles were eligible for data extraction, of which 9 were case-control studies reporting on 929 custom versus 998 OTS TKA, 5 were case series reporting on results of 587 custom TKA, and 1 was a cross-sectional study reporting on results of 44 custom versus 132 OTS TKA. Five studies that compared early revision rates found the overall effect in favour of OTS TKA (odds ratio (OR), 0.4; p = n.s.) but the result did not reach statistical significance. Four studies found no statistically significant difference in KSS knee (standardised mean difference (SMD), - 0.10; p = n.s.) and function (SMD, 0.03; p = n.s.), and five studies found no statistically significant difference in range of motion (SMD, 0.02; p = n.s.). One study that compared bone-implant fit between custom and three OTS tibial components found no overhang but revealed under-coverage of up to 18% in knees with custom tibial baseplates.
conclusionCustom TKA demonstrated no significant benefits compared to OTS TKA in terms of pooled clinical outcomes, but had considerably higher early revision rates. The findings of the present systematic review and meta-analysis suggest the need for studies with better comparable groups and standardisation of reporting outcomes amongst studies, that could increase the quality of evidence and enable pooling of results in future meta-analyses. LEVEL OF EVIDENCE: Level IV.