Evidence map›Paper›PMID 34431520›Full record

ArticleMedical physics2021

A simulation study of ionizing radiation acoustic imaging (iRAI) as a real-time dosimetric technique for ultra-high dose rate radiotherapy (UHDR-RT).

Noora H Ba Sunbul, Wei Zhang, Ibrahim Oraiqat, Dale W Litzenberg, Kwok L Lam, Kyle Cuneo, Jean M Moran, Paul L Carson, Xueding Wang, Shaun D Clarke and 3 more

Abstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. 4DPhysics in medicine and biology · 2024
    Article
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Noora H Ba SunbulDepartment of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, Michigan, USA.
Wei ZhangDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Ibrahim OraiqatDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan, USA.
Dale W LitzenbergDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan, USA.
Kwok L LamDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan, USA.
Kyle CuneoDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan, USA.
Jean M MoranDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan, USA.
Paul L CarsonDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Xueding WangDepartment of Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Shaun D ClarkeDepartment of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, Michigan, USA.
Martha M MatuszakDepartment of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, Michigan, USA.
Sara A PozziDepartment of Nuclear Engineering and Radiological Sciences, University of Michigan, Ann Arbor, Michigan, USA.
Issam El NaqaDepartment of Radiation Oncology, University of Michigan, Ann Arbor, Michigan, USA.

Funding

Combined radiation acoustics and ultrasound imaging for real-time guidance in radiotherapyR37CA222215 · NCI · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI EL NAQA, ISSAM M. · 2018 to 2024
$3.5M
NCI NIH HHS R37 CA222215NIH HHS R37CA222215
6 · The paper itself

Abstract

purposeElectron-based ultra-high dose rate radiation therapy (UHDR-RT), also known as Flash-RT, has shown the ability to improve the therapeutic index in comparison to conventional radiotherapy (CONV-RT) through increased sparing of normal tissue. However, the extremely high dose rates in UHDR-RT have raised the need for accurate real-time dosimetry tools. This work aims to demonstrate the potential of the emerging technology of Ionized Radiation Acoustic Imaging (iRAI) through simulation studies and investigate its characteristics as a promising relative in vivo dosimetric tool for UHDR-RT.

methodsThe detection of induced acoustic waves following a single UHDR pulse of a modified 6 MeV 21EX Varian Clinac in a uniform porcine gelatin phantom that is brain-tissue equivalent was simulated for an ideal ultrasound transducer. The full 3D dose distributions in the phantom for a 1 × 1 cm

resultsThe MC dose simulation results agreed with the film measurement results, specifically at the central beam region up to 80% dose within approximately 5% relative error for the central profile region and a local relative error of <6% for percentage dose depth. IRAI-based FWHM of the radiation beam was within approximately 3 mm relative to the MC-simulated beam FWHM at the beam entrance. The real-time pressure signal change agreed with the dose changes proving the capability of the iRAI for predicting the beam position. IRAI was tested through 3D simulations of its response to be based on the temporal changes in the linac operating parameters on a dose per pulse basis as expected theoretically from the pressure-dose proportionality. The pressure signal amplitude obtained through 2D simulations was proportional to the dose per pulse. The instantaneous pressure signal amplitude decreases as the linac pulse duration increases, as predicted from the pressure wave generation equations, such that the shorter the linac pulse the higher the signal and the better the temporal (spatial) resolutions of iRAI. The effect of the longer linac pulse duration on the spatial resolution of the 3D constructed iRAI images was corrected for linac pulse deconvolution. This correction has improved the passing rate of the 1%/1 mm gamma test criteria, between the pressure-constructed and dosimetric beam characteristics, to as high as 98%.

conclusionsA full simulation workflow was developed for testing the effectiveness of iRAI as a promising relative dosimetry tool for UHDR-RT radiation therapy. IRAI has shown the advantage of 3D dose mapping through the dose signal linearity and, hence, has the potential to be a useful dosimeter at depth dose measurement and beam localization and, hence, potentially for in vivo dosimetry in UHDR-RT.

Indexed as

Particle AcceleratorsRadiometryAcousticsAnimalsMonte Carlo MethodPhantoms, ImagingRadiation, IonizingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedSwinein vivo dosimetryMonte Carloradiation acousticsUHDR (Flash) radiotherapy

Identifiers

PMID34431520
PMCPMC8943858

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.