Evidence map›Paper›PMID 34431249›Full record

ArticleKorean journal of radiology2021

Deep Learning-Based Algorithm for the Detection and Characterization of MRI Safety of Cardiac Implantable Electronic Devices on Chest Radiographs.

Ue-Hwan Kim, Moon Young Kim, Eun-Ah Park, Whal Lee, Woo-Hyun Lim, Hack-Lyoung Kim, Sohee Oh, Kwang Nam Jin

Abstract read
In one paragraph

Article in Korean journal of radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Ue-Hwan Kim *School of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Korea.ORCID 0000-0003-2201-2988
Moon Young Kim *Department of Radiology, SMG-SNU Boramae Medical Center, Seoul, Korea.ORCID 0000-0003-3025-0409
Eun-Ah ParkDepartment of Radiology, Seoul National University Hospital, Seoul, Korea.ORCID 0000-0001-6203-1070
Whal LeeDepartment of Radiology, Seoul National University Hospital, Seoul, Korea.ORCID 0000-0003-1285-5033
Woo-Hyun LimDivision of Cardiology, Department of Internal Medicine, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Korea.ORCID 0000-0001-9298-8500
Hack-Lyoung KimDivision of Cardiology, Department of Internal Medicine, SMG-SNU Boramae Medical Center, Seoul National University College of Medicine, Seoul, Korea.ORCID 0000-0002-6703-1472
Sohee OhMedical Research Collaborating Center, Seoul National University Boramae Medical Center, Seoul, Korea.ORCID 0000-0002-3010-448X
Kwang Nam JinDepartment of Radiology, SMG-SNU Boramae Medical Center, Seoul, Korea. wlsrhkdska@gmail.com.ORCID 0000-0001-5494-9113

Funding

Radiological Research Foundation of Korea 2018-01Seoul Metropolitan Government Seoul National University Boramae Medical Center 03-2019-26
6 · The paper itself

Abstract

objectiveWith the recent development of various MRI-conditional cardiac implantable electronic devices (CIEDs), the accurate identification and characterization of CIEDs have become critical when performing MRI in patients with CIEDs. We aimed to develop and evaluate a deep learning-based algorithm (DLA) that performs the detection and characterization of parameters, including MRI safety, of CIEDs on chest radiograph (CR) in a single step and compare its performance with other related algorithms that were recently developed. MATERIALS AND

methodsWe developed a DLA (X-ray CIED identification [XCID]) using 9912 CRs of 958 patients with 968 CIEDs comprising 26 model groups from 4 manufacturers obtained between 2014 and 2019 from one hospital. The performance of XCID was tested with an external dataset consisting of 2122 CRs obtained from a different hospital and compared with the performance of two other related algorithms recently reported, including PacemakerID (PID) and Pacemaker identification with neural networks (PPMnn).

resultsThe overall accuracies of XCID for the manufacturer classification, model group identification, and MRI safety characterization using the internal test dataset were 99.7% (992/995), 97.2% (967/995), and 98.9% (984/995), respectively. These were 95.8% (2033/2122), 85.4% (1813/2122), and 92.2% (1956/2122), respectively, with the external test dataset. In the comparative study, the accuracy for the manufacturer classification was 95.0% (152/160) for XCID and 91.3% for PPMnn (146/160), which was significantly higher than that for PID (80.0%,128/160;

conclusionThe remarkable and consistent performance of XCID suggests its applicability for detection, manufacturer and model identification, as well as MRI safety characterization of CIED on CRs. Further studies are warranted to guarantee the safe use of XCID in clinical practice.

Indexed as

Deep LearningDefibrillators, ImplantablePacemaker, ArtificialAlgorithmsElectronicsHumansMagnetic Resonance ImagingCardiac implantable electronic deviceDeep learningImplantable cardioverter defibrillatorPacemakerRadiography

Identifiers

PMID34431249
PMCPMC8546129

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.