Real-time respiratory motion compensated roadmaps for hepatic arterial interventions.
Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Joint Temporal and Spectral Processing for Improved Digital Subtraction Angiography Using Photon-Counting Detectors.IEEE transactions on bio-medical engineering · 2025Article
- Hepatic Histotripsy: Jet Ventilation Decreases the Effect of Respiratory Motion in A Porcine Liver Model.Cardiovascular and interventional radiology · 2025Article
- Real-time continuous image guidance for endoscopic retrograde cholangiopancreatography based on 3D/2D registration and respiratory compensation.World journal of gastroenterology · 2023Article
- An X-Ray C-Arm Guided Automatic Targeting System for Histotripsy.IEEE transactions on bio-medical engineering · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
purposeDuring hepatic arterial interventions, catheter or guidewire position is determined by referencing or overlaying a previously acquired static vessel roadmap. Respiratory motion leads to significant discrepancies between the true position and configuration of the hepatic arteries and the roadmap, which makes navigation and accurate catheter placement more challenging and time consuming. The purpose of this work was to develop a dynamic respiratory motion compensated device guidance system and evaluate the accuracy and real-time performance in an in vivo porcine liver model.
methodsThe proposed device navigation system estimates a respiratory motion model for the hepatic vasculature from prenavigational X-ray image sequences acquired under free-breathing conditions with and without contrast enhancement. During device navigation, the respiratory state is tracked based on live fluoroscopic images and then used to estimate vessel deformation based on the previously determined motion model. Additionally, guidewires and catheters are segmented from the fluoroscopic images using a deep learning approach. The vessel and device information are combined and shown in a real-time display. Two different display modes are evaluated within this work: (1) a compensated roadmap display, where the vessel roadmap is shown moving with the respiratory motion; (2) an inverse compensated device display, where the device representation is compensated for respiratory motion and overlaid on a static roadmap. A porcine study including seven animals was performed to evaluate the accuracy and real-time performance of the system. In each pig, a guidewire and microcatheter with a radiopaque marker were navigated to distal branches of the hepatic arteries under fluoroscopic guidance. Motion compensated displays were generated showing real-time overlays of the vessel roadmap and intravascular devices. The accuracy of the motion model was estimated by comparing the estimated vessel motion to the motion of the X-ray visible marker.
resultsThe median (minimum, maximum) error across animals was 1.08 mm (0.92 mm, 1.87 mm). Across different respiratory states and vessel branch levels, the odds of the guidewire tip being shown in the correct vessel branch were significantly higher (odds ratio = 3.12, p < 0.0001) for motion compensated displays compared to a noncompensated display (median probabilities of 86 and 69%, respectively). The average processing time per frame was 17 ms.
conclusionsThe proposed respiratory motion compensated device guidance system increased the accuracy of the displayed device position relative to the hepatic vasculature. Additionally, the provided display modes combine both vessel and device information and do not require the mental integration of different displays by the physician. The processing times were well within the range of conventional clinical frame rates.