Evidence map›Paper›PMID 34431026›Full record

ArticleMedical & biological engineering & computing2021

Feasibility of extracting tissue material properties via cohesive elements: a finite element approach to probe insertion procedures in non-invasive spine surgeries.

Ibrahim El Bojairami, Amirhossein Hamedzadeh, Mark Driscoll

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
1.9field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 11 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Ibrahim El BojairamiDepartment of Mechanical Engineering, Musculoskeletal Biomechanics Research Laboratory McGill University, Macdonald Eng. Bldg. Office #153, 817 Sherbrooke Street West, Montréal, QC, H3A 0C3, Canada.
Amirhossein HamedzadehDepartment of Mechanical Engineering, Musculoskeletal Biomechanics Research Laboratory McGill University, Macdonald Eng. Bldg. Office #153, 817 Sherbrooke Street West, Montréal, QC, H3A 0C3, Canada.
Mark DriscollDepartment of Mechanical Engineering, Musculoskeletal Biomechanics Research Laboratory McGill University, Macdonald Eng. Bldg. Office #153, 817 Sherbrooke Street West, Montréal, QC, H3A 0C3, Canada. mark.driscoll@mcgill.ca.ORCID http://orcid.org/0000-0002-5348-6054
McGill University · CA

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Modeling the mechanical behavior of soft tissue probe insertion remains a challenging endeavor due to involved interdependent phenomena comprising tissue nonlinear deformation, contact between the probe and the tissue, crack propagation, and viscoelastic effects. To that matter, cohesive elements allow simulating crack formation and propagation, which provides a promising path to modeling the mechanical behavior of probe insertion in soft tissues. As such, the aim of the present study was to investigate the feasibility of devising and integrating an algorithm in a finite element (FE) case study in efforts of reverse engineering the material properties of non-homogeneous soft tissues. A layered nonlinear tissue model with a cohesive zone was created in the commercial software ABAQUS. Material properties were iteratively modified via a hybrid gradient descent optimization algorithm: minimizing the resultant error to first find optimum Ogden's hyperelastic parameters, followed by obtaining the damage parameters. Perceived material properties were then compared to those obtained via experimental human cadaver testing. Under the investigated four-layered muscle model, numerical results overlapped, to a great extent, with six different force-insertion experimental profiles with an average error of [Formula: see text] 15%. The best profile fit was realized when the highest sudden force drop was less than 60% of the peak force. Lastly, the FE analysis revealed an increase in stiffness as the probe advanced inside the tissue. The optimization algorithm demonstrated its capability to reverse engineer the material parameters required for the FE analysis of real, non-homogeneous, soft tissues. The significance of this procedure lies within its ability to extract tissue material parameters, in real time, with little to no intervention or invasive experimental tests. This could potentially further serve as a database for different muscle layers and force-insertion profiles, used for surgeon and physician clinical training purposes.

Indexed as

Biomechanical PhenomenaFinite Element AnalysisNonlinear DynamicsSoftwareElasticityFeasibility StudiesHumansModels, BiologicalStress, MechanicalCohesive elementsFinite element analysisOptimization algorithmsProbe insertionTissue material properties

Identifiers

PMID34431026
OpenAlexW3195759888

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.