ArticleHeart rhythm O22021

Evaluation of different ablation strategies verifying the optimal overlap ratio in point-by-point laser balloon ablation for patients with atrial fibrillation.

Takahiko Nagase, Ruiko Seki, So Asano, Hiroshi Fukunaga, Kazuhiro Terashima, Kei Mabuchi, Kanki Inoue, Kohei Tanizaki, Nobuo Iguchi, Junichi Nitta and 1 more

Open access · goldAbstract read
In one paragraph

Article in Heart rhythm O2, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.5field-weighted citation impact, top 34% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Is creation of a fully circumferential lesion set necessary for laser balloon ablation-based pulmonary vein isolation?Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2023
    Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 1 institution in 1 country.

Takahiko NagaseDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Ruiko SekiDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
So AsanoDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Hiroshi FukunagaDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Kazuhiro TerashimaDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Kei MabuchiDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Kanki InoueDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Kohei TanizakiDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Nobuo IguchiDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Junichi NittaDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Mitsuaki IsobeDepartment of Cardiology, Sakakibara Heart Institute, Tokyo, Japan.
Sakakibara Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOptimal overlap ratio remains unclear in point-by-point laser balloon (LB) ablation.

objectiveThis study sought to determine the optimal overlap strategy with target energies on the acute and chronic outcomes in LB pulmonary vein (PV) isolation (PVI).

methodsConsecutive 38 patients (148 PVs) with atrial fibrillation underwent the first-generation LB PVI with the following protocols based on the overlap ratios for each PV anterior/posterior wall: 50%/50% (13 patients [49 PVs], group A), 50%/25% (15 patients [60 PVs], group B), and 25%/25% (10 patients [39 PVs], group C). High energies (240-255 J: 12 W / 20 seconds, 8.5 W / 30 seconds), moderate energies (200-210 J: 10 W / 20 seconds, 7 W / 30 seconds), and low-to-moderate energies (low, 165-170 J: 5.5 W / 30 seconds, 8.5 W / 20 seconds) were targeted for left PV anterior walls, right PV anterior walls, and bilateral PV posterior walls, respectively. First-pass PVI, the other procedure-related data, and atrial tachyarrhythmia recurrences were analyzed.

resultsFirst-pass PVI rate per PV was higher in group A (94%) than in group B (88%) and group C (62%) (

conclusionSufficiently overlapped LB ablation promises a high rate of first-pass PVI without adverse outcomes. High energy could be required for PV anterior walls.

Indexed as

Atrial fibrillationOptimal energyOptimal overlap ratioPoint-by-point laser balloon ablationPulmonary vein isolation

Identifiers

PMID34430940
PMCPMC8369302
OpenAlexW3174463413

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.