Article... International Symposium on Medical Robotics. International Symposium on Medical Robotics2020

FBG-based Kalman Filtering and Control of Tool Insertion Depth For Safe Robot-assisted Vitrectomy.

Ali Ebrahimi, Muller Urias, Niravkumar Patel, Peter Gehlbach, Farshid Alambeigi, Iulian Iordachita

Abstract read
In one paragraph

Article in ... International Symposium on Medical Robotics. International Symposium on Medical Robotics, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ali EbrahimiDepartment of Mechanical Engineering and the Laboratory for Computational Sensing and Robotics at the Johns Hopkins University, Baltimore, MD 21218 USA.
Muller UriasWilmer Eye Institute, Johns Hopkins Hospital, Baltimore, MD 21287 USA.
Niravkumar PatelDepartment of Mechanical Engineering and the Laboratory for Computational Sensing and Robotics at the Johns Hopkins University, Baltimore, MD 21218 USA.
Peter GehlbachWilmer Eye Institute, Johns Hopkins Hospital, Baltimore, MD 21287 USA.
Farshid AlambeigiWalker Department of Mechanical Engineering at the University of Texas at Austin, Austin, TX, 78712, USA.
Iulian IordachitaDepartment of Mechanical Engineering and the Laboratory for Computational Sensing and Robotics at the Johns Hopkins University, Baltimore, MD 21218 USA.

Funding

Enabling Technology for Safe Robot-assisted Surgical MicromanipulationR01EB023943 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI GEHLBACH, PETER LOUIS, IORDACHITA, IULIAN IOAN · 2017 to 2024
$2.3M
NIBIB NIH HHS R01 EB023943
6 · The paper itself

Abstract

Vitrectomy is that portion of retinal surgery in which the vitreous gel is removed either as a definitive treatment or to provide direct tool access to the retina. This procedure should be conducted prior to several eye surgeries in order to provide better access to the eyeball posterior. It is a relatively repeatable and straight forward procedure that lends itself to robotic assistance or potentially autonomous performance if tool contact with critical structures can be avoided. One of the detrimental incidences that can occur during the robot-assisted vitrectomy is when the robot penetrates the tool more than allowed boundaries into the eyeball toward retina. In this paper, we provide filtering and control to guide instrument insertion depth in order to avoid tool-to-retina contact. For this purpose, first the tool insertion depth measurement is improved using a Kalman filtering (KF) algorithm. This improved measurement is then used in an adaptive control strategy by which the robot reduces the tool insertion depth based on a predefined and safe trajectory for it, when safe boundaries are overstepped. The performance of the insertion depth safety control system is then compared to one in which the insertion depth is not passed through a Kalman filter prior to being fed to the control system. Our results indicate that applying KF in the adaptive control of the robot enhances procedure safety and enables the robot to always keep the tool insertion depth under the safe levels.