ArticleIEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation
A Fully Actuated Body-Mounted Robotic Assistant for MRI-Guided Low Back Pain Injection.
Article in IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 21 citations in OpenAlex.
- MRI guided HIFU robotic system application in feasibility study for treating uterine fibroids.Scientific reports · 2025Article
- Toward Autonomous Marker Localization for Lumbar Epidural Steroid Injection Robot.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024Article
- Modeling and Control of an MR-Safe Pneumatic Radial Inflow Motor and Encoder (PRIME).IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2024Article
- A magnetic resonance conditional robot for lumbar spinal injection: Development and preliminary validation.The international journal of medical robotics + computer assisted surgery : MRCAS · 2024Article
- Non-Metallic MR-Guided Concentric Tube Robot for Intracerebral Hemorrhage Evacuation.IEEE transactions on bio-medical engineering · 2023Article
- Flexible Needle Bending Model for Spinal Injection Procedures.IEEE robotics and automation letters · 2023Article
- Fluoroscopy-Guided Robotic System for Transforaminal Lumbar Epidural Injections.IEEE transactions on medical robotics and bionics · 2022Article
- An MR-Conditional Needle Driver for Robot-Assisted Spinal Injections: Design Modifications and Evaluations.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2022Article
- State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022Article
- Body-Mounted Robotics for Interventional MRI Procedures.IEEE transactions on medical robotics and bionics · 2020Article
- Fully Actuated Body-Mounted Robotic System for MRI-Guided Lower Back Pain Injections: Initial Phantom and Cadaver Studies.IEEE robotics and automation letters · 2020Article
- Design of a 6-DoF Parallel Robotic Platform for MRI Applications.Journal of medical robotics researchArticle
- Towards Safe In Situ Needle Manipulation for Robot Assisted Lumbar Injection in Interventional MRI.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and SystemsArticle
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
This paper reports the development of a fully actuated body-mounted robotic assistant for MRI-guided low back pain injection. The robot is designed with a 4-DOF needle alignment module and a 2-DOF remotely actuated needle driver module. The 6-DOF fully actuated robot can operate inside the scanner bore during imaging; hence, minimizing the need of moving the patient in or out of the scanner during the procedure, and thus potentially reducing the procedure time and streamlining the workflow. The robot is built with a lightweight and compact structure that can be attached directly to the patient's lower back using straps; therefore, attenuating the effect of patient motion by moving with the patient. The novel remote actuation design of the needle driver module with beaded chain transmission can reduce the weight and profile on the patient, as well as minimize the imaging degradation caused by the actuation electronics. The free space positioning accuracy of the system was evaluated with an optical tracking system, demonstrating the mean absolute errors (MAE) of the tip position to be 0.99±0.46 mm and orientation to be 0.99±0.65°. Qualitative imaging quality evaluation was performed on a human volunteer, revealing minimal visible image degradation that should not affect the procedure. The mounting stability of the system was assessed on a human volunteer, indicating the 3D position variation of target movement with respect to the robot frame to be less than 0.7 mm.