ArticleClean technologies and environmental policy2022
Biomimetic building facades demonstrate potential to reduce energy consumption for different building typologies in different climate zones.
Article in Clean technologies and environmental policy, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed, 39 citations in OpenAlex.
- Editorial for Special Issue on Biomimetic Adaptive Buildings.Biomimetics (Basel, Switzerland) · 2025Article
- What Inspires Biomimicry in Construction? Patterns, Trends, and Applications.Biomimetics (Basel, Switzerland) · 2025Review
- Plants Inspired Biomimetics Architecture in Modern Buildings: A Review of Form, Function and Energy.Biomimetics (Basel, Switzerland) · 2025Review
- Biomimicry Industry and Patent Trends.Biomimetics (Basel, Switzerland) · 2023Article
- Environmentally Responsive Materials for Building Envelopes: A Review on Manufacturing and Biomimicry-Based Approaches.Biomimetics (Basel, Switzerland) · 2023Review
- Special Issue: Biomimetic Organic-Inorganic Composites.Materials (Basel, Switzerland) · 2022Article
- Biomimicry for Energy-Efficient Building Design: A Bibliometric Analysis.Biomimetics (Basel, Switzerland) · 2022Article
- Numerical Assessment of Zebra-Stripes-Based Strategies in Buildings Energy Performance: A Case Study under Tropical Climate.Biomimetics (Basel, Switzerland) · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
1 author at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Greenhouse gas (GHG) emissions leading to anthropogenic global warming continue to be a major issue for societies worldwide. A major opportunity to reduce emissions is to improve building construction, and in particular the effectiveness of building envelope, which leads to a decrease in operational energy consumption. Improving the performance of a building's thermal envelope can substantially reduce energy consumption from heating, ventilation, and air conditioning while maintaining occupant comfort. In previous work, a computational model of a biomimetic building façade design was found to be effective in temperate climates in an office context. Through a case study example based on animal fur and blood perfusion, this paper tests the hypothesis that biomimetic building facades have a broader application in different building typologies across a range of climate zones. Using bioinspiration for innovation opens new ideas and pathways for technological development that traditional engineering design does not provide. This study exemplifies the process in a building façade, integrating a new form of insulation, heating and cooling. Methods of mathematical modelling and digital simulation methods were used to test the energy reduction potential of the biomimetic façade was tested in a set of operational applications (office, school, and aged care) and across different climate zones (tropical, desert, temperate, and cool continental). Results indicated that the biomimetic façade has potential to reduce energy consumption for all building applications, with the greatest benefit shown in residential aged care (67.1% reduction). Similarly, the biomimetic building façade showed potential to reduce operational services energy consumption in all climate zones, with the greatest energy reductions achieved in the tropical (55.4% reduction) and humid continental climates (55.1% reduction). Through these results the hypothesis was confirmed suggesting that facades engineered to mimic biological functions and processes can improve substantially decrease building operational energy consumption and can be applied in different building classifications and different climate zones. These results would significantly decrease operational greenhouse gas emissions over the lifetime of a building and provide substantial savings in energy bills. Such facades can contribute to the further reduction in greenhouse gas emissions in a broad range of contexts in the built environment and other areas of technology and design. The flexibility and adaptability of biomimetic facades exemplify how biological strategies and characteristics can augment and improve performance in different environments, since the organisms that inspire innovation are already well-adapted to the conditions on earth. This study also exemplified a method by which other biomimetic building envelope features may be assessed. Further work is suggested to assess economic viability and constructability of the proposed facades. Graphic abstract:
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.