Evidence map›Paper›PMID 34416552›Full record

ArticleJournal of pharmaceutical and biomedical analysis2021

Quantification of anti-SARS-CoV-2 antibodies in human serum with LC-QTOF-MS.

Karen A M de Jong, Hilde Rosing, Marit Vermunt, Alwin D R Huitema, Jos H Beijnen

Abstract read
In one paragraph

Article in Journal of pharmaceutical and biomedical analysis, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Biophysical principles predict fitness of SARS-CoV-2 variants.Proceedings of the National Academy of Sciences of the United States of America · 2024
    Article
  4. Biophysical principles predict fitness of SARS-CoV-2 variants.bioRxiv : the preprint server for biology · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Karen A M de JongDepartment of Pharmacy & Pharmacology, Antoni van Leeuwenhoek/The Netherlands Cancer Institute, Amsterdam, The Netherlands. Electronic address: Ka.d.jong@nki.nl.
Hilde RosingDepartment of Pharmacy & Pharmacology, Antoni van Leeuwenhoek/The Netherlands Cancer Institute, Amsterdam, The Netherlands.
Marit VermuntDepartment of Pharmacy & Pharmacology, Antoni van Leeuwenhoek/The Netherlands Cancer Institute, Amsterdam, The Netherlands.
Alwin D R HuitemaDepartment of Pharmacy & Pharmacology, Antoni van Leeuwenhoek/The Netherlands Cancer Institute, Amsterdam, The Netherlands; Department of Clinical Pharmacy, University Medical Center Utrecht, Utrecht, The Netherlands; Department of Pharmacology, Princess Máxima Center for Pediatric Oncology, Utrecht, The Netherlands.
Jos H BeijnenDepartment of Pharmacy & Pharmacology, Antoni van Leeuwenhoek/The Netherlands Cancer Institute, Amsterdam, The Netherlands; Division of Pharmacoepidemiology and Clinical Pharmacology, Faculty of Science, Department of Pharmaceutical Sciences, Utrecht University, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim of this study was to develop the first quantitative serological test for anti-SARS-CoV-2 antibodies in human serum with liquid chromatography - quadrupole time-of-flight mass spectrometry (LC-QTOF-MS). Other assays, mostly immunoassays, are only qualitative or semi-quantitative, and hence, actual antibody concentrations after SARS-CoV-2 infection are unknown. In our assay, anti-SARS-CoV-2 antibodies were isolated with spike protein subunit 1 (S1) coupled to magnetic beads. IgG1 signature peptide GPSVFPLAPSSK was selected for quantification using ipilimumab calibration standards and SILuMAb K1 as the stable-isotope labeled internal standard. The anti-SARS-CoV-2 IgG1 calibration range was from 1.35 to 135 nM. Inter-assay accuracies were between 98.8%- 107% with inter-assay precisions between 8.37%- 13.5% measured at 3 concentration levels on three separate occasions. Anti-SARS-CoV-2 IgG1 antibodies were quantified in PCR-positive patients with mild to severe symptoms. IgM signature peptide DGFFGVPR was detected in patients that recently recovered from COVID-19. A unique and quantitative LC-QTOF-MS method to quantify anti-SARS-CoV-2 IgG1 in serum was successfully developed and its clinical applicability has been demonstrated.

Indexed as

COVID-19SARS-CoV-2Chromatography, LiquidHumansImmunoglobulin GTandem Mass SpectrometryImmunoglobulin GAnti-SARS-CoV-2 antibodiesCOVID-19LC-QTOF-MSMass spectrometrySARS-CoV-2Spike protein

Identifiers

PMID34416552
PMCPMC8354797

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked