Evidence map›Paper›PMID 34415437›Full record

ArticleSurgery today2022

The impact of the quantitative assessment procedure for coronary artery bypass graft evaluations using high-resolution near-infrared fluorescence angiography.

Masaki Yamamoto, Hitoshi Ninomiya, Takemi Handa, Koichi Kidawawa, Keiji Inoue, Takayuki Sato, Kazuhiro Hanazaki, Kazumasa Orihashi

Abstract read
PubMed Publisher
In one paragraph

Article in Surgery today, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Guiding esophagectomy with intraoperative NIR-II fluorescence video imaging and rapid computation.Proceedings of the National Academy of Sciences of the United States of America · 2025
    Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Masaki YamamotoDepartment of Surgery, Kidawara Hospital, Nakamura Ichijoh-dohri 3-3-25, Shimanto City, Kochi, 787-0025, Japan. m_yamamoto@kidawara-hp.net.
Hitoshi NinomiyaDepartment of Civil and Environmental Engineering, Toyo University, Kawagoe City, Saitama, 350-8585, Japan.
Takemi HandaDepartment of Surgery 2, Kochi Medical School, Kochi University, Nankoku City, Kochi, 783-8505, Japan.
Koichi KidawawaDepartment of Surgery, Kidawara Hospital, Nakamura Ichijoh-dohri 3-3-25, Shimanto City, Kochi, 787-0025, Japan.
Keiji InoueCenter for Photodynamic Medicine, Kochi Medical School, Kochi University, Nankoku City, Kochi, 783-8505, Japan.
Takayuki SatoCenter for Photodynamic Medicine, Kochi Medical School, Kochi University, Nankoku City, Kochi, 783-8505, Japan.
Kazuhiro HanazakiCenter for Photodynamic Medicine, Kochi Medical School, Kochi University, Nankoku City, Kochi, 783-8505, Japan.
Kazumasa OrihashiDepartment of Surgery 2, Kochi Medical School, Kochi University, Nankoku City, Kochi, 783-8505, Japan.
Kōchi University · JPKochi Medical School Hospital · JPToyo University · JP

Funding

the Japan Society for the Promotion of Science KAKENHI 20437718
6 · The paper itself

Abstract

purposeNear-infrared angiography (NIR) is used for on-site graft assessment during coronary artery bypass grafting. This study evaluated the results of a quantitative NIR assessment using a new high-resolution NIR device (h-NIR) for graft assessment.

methodsForty-three patients were enrolled in our study. Internal thoracic artery (ITA) grafts anastomosed to the left anterior descending artery and examined intraoperatively using h-NIR were included. The ITA grafts were divided into 2 groups for a comparative analysis: patent grafts (P group; n = 37) and failed grafts (F group; n = 6). The graft flow was evaluated by a "quantitative NIR assessment", and the fluorescence luminance intensity (FLI) was measured. Direct observation of the graft and anastomosis with h-NIR was also performed.

resultsThe FLI was higher in the P group than in the F group. The receiver operating characteristic analysis revealed the following cut-off values for FLIs depending on imaging duration: 21.1% at 1 s, 35.5% at 2 s, 58.4% at 3 s, and 83.3% at 4 s. The sensitivity and specificity for detecting graft failure were 83.3% and 69.8-80.6%, respectively. Furthermore, h-NIR was also able to visualize arterial dissection in ITA grafts.

conclusionsA quantitative NIR assessment with an h-NIR device can improve the detectability of anastomotic stenosis, and h-NIR successfully detected arterial dissection of grafts.

Indexed as

Coronary Artery BypassMammary ArteriesAnastomosis, SurgicalCoronary AngiographyFluorescein AngiographyHumansVascular PatencyCoronary artery bypass graftingFluorescence luminance intensityHigh-resolution near-infrared angiographyInternal thoracic arteryNear-infrared angiography

Identifiers

PMID34415437
OpenAlexW3195675850

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked