Evidence map›Paper›PMID 34409216›Full record

ReviewAdvances in radiation oncology

A Review and Analysis of Managing Commonly Seen Implanted Devices for Patients Undergoing Radiation Therapy.

Maria F Chan, Claire Young, Daphna Gelblum, Chengyu Shi, Carolanne Rincon, Elizabeth Hipp, Jingdong Li, Dongxu Wang

Open access · goldAbstract readReview
In one paragraph

Review in Advances in radiation oncology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
3.8field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Advances in radiation oncology
    Article
  7. ASTRO'sAdvances in radiation oncology
    Article
  8. Article
  9. American Society for Radiation Oncology'sAdvances in radiation oncology
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Maria F ChanDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY.
Claire YoungDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY.
Daphna GelblumDepartment of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY.
Chengyu ShiDepartment of Medical Physics, New York Proton Center, New York, NY.
Carolanne RinconDepartment of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY.
Elizabeth HippDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY.
Jingdong LiDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY.
Dongxu WangDepartment of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY.
Memorial Sloan Kettering Cancer Center · USNew York Proton Center · US

Funding

X-RAY CRYSTALLOGRAPHYP30CA008748 · NCI · SLOAN-KETTERING INSTITUTE FOR CANCER RES · PI Nicholas D Socci · 1985 to 2026
$347.4M
NCI NIH HHS P30 CA008748
6 · The paper itself

Abstract

purposeThis review article aims to consolidate information regarding existing and emerging implanted devices used in patients undergoing radiation therapy and to categorize levels of attention needed for each device, including which devices require monitoring throughout treatment. METHODS AND MATERIALS: Based on the collective information from scholar searches, manufacturers' technical reports, and institutional experiences in the past years, commonly present devices in patients with cancer are compiled. This work summarizes cardiac pacemaker, implanted cardiac defibrillator, hepatic pump, intrathecal pain pump, neurostimulator, shunt, loop recorder, and mediport. Three different classifications of implanted devices can be made based on the potential effect of radiation: life-dependent, nonlife-dependent but with adverse effects if overdosed, and devices without electronic circuits. Implanted devices that contain electronic circuits that would be life-dependent or have adverse effects if overdosed, include cardiac pacemakers, implanted cardiac defibrillators, programmable hepatic pumps, pain pumps, neurostimulators, and loop recorders.

resultsDose exposure to these devices need to be calculated or measured in vivo

conclusionsThis study reviewed the management of patients with commonly seen implanted devices and summarized a workflow for identifying and planning when a patient has implanted devices. Classifications of implanted devices could help clinicians make proper decisions in regard to patients with specific implanted devices. Lastly, the management of such devices in the era of the pandemic is also discussed in this review article.

Identifiers

PMID34409216
PMCPMC8361059
OpenAlexW3191246308

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.