ArticleMedical physics2021

Tomography of dark-field scatter including single-exposure Moiré fringe analysis with X-ray biprism interferometry-A simulation study.

Weijie Tao, Yongjin Sung, Sally Ji Who Kim, Qiu Huang, Grant T Gullberg, Youngho Seo, Michael Fuller

Abstract read
In one paragraph

Article in Medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Weijie TaoDepartment of Nuclear Medicine, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Yongjin SungDepartment of Biomedical and Mechanical Engineering, University of Wisconsin-Milwaukee, Milwaukee, WI, USA.
Sally Ji Who KimCardiovascular Research Center, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA.
Qiu HuangDepartment of Nuclear Medicine, Rui Jin Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, China.
Grant T GullbergDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
Youngho SeoDepartment of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA.
Michael FullerTF Instruments, Salinas, CA, USA.

Funding

Energy-independent single photon molecular imaging technologyR01EB026331 · NIBIB · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI CUI, YONGGANG, SEO, YOUNGHO · 2018 to 2022
$2.6M
Dynamic cardiac SPECTR01HL135490 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI GULLBERG, GRANT T, SEO, YOUNGHO · 2017 to 2020
$2.4M
Preclinical Dark-Field/Phase-Contrast Scanner Using X-ray BiprismsR43EB027535 · NIBIB · TF INSTRUMENTS · PI FULLER, MICHAEL KEITH, SEO, YOUNGHO · 2018 to 2018
$225k
China Scholarship Council 201906230215NHLBI NIH HHS R01 HL135490NIBIB NIH HHS R01 EB026331NIBIB NIH HHS R43 EB027535NIH HHS R01 EB026331NIH HHS R01 HL135490NIH HHS R43 EB027535
6 · The paper itself

Abstract

purposeIn this work, we present tomographic simulations of a new hardware concept for X-ray phase-contrast interferometry wherein the phase gratings are replaced with an array of Fresnel biprisms, and Moiré fringe analysis is used instead of "phase stepping" popular with grating-based setups.

methodsProjections of a phantom consisting of four layers of parallel carbon microfibers is simulated using wave optics representation of X-ray electromagnetic waves. Simulated projections of a phantom with preferential scatter perpendicular to the direction of the fibers are performed to analyze the extraction of small-angle scatter from dark-field projections for the following: (1) biprism interferometry using Moiré fringe analysis; (2) grating interferometry using phase stepping with eight grating steps; and (3) grating interferometry using Moiré fringe analysis. Dark-field projections are modeled as projections of voxel intensities represented by a fixed finite vector basis set of scattering directions. An iterative MLEM algorithm is used to reconstruct, from simulated projection data, the coefficients of a fixed set of seven basis vectors at each voxel representing the small-angle scatter distribution.

resultsResults of reconstructed vector coefficients are shown comparing the three simulated imaging configurations. The single-exposure Moiré fringe analysis shows not only an increase in noise because of one-eighth the number of projection samples but also is obtained with less dose and faster acquisition times. Furthermore, replacing grating interferometry with biprism interferometry provides better contrast-to-noise.

conclusionThe simulations demonstrate the feasibility of the reconstruction of dark-field data acquired with a biprism interferometry system. With the potential of higher fringe visibility, biprism interferometry with Moiré fringe analysis might provide equal or better image quality to that of phase stepping methods with less imaging time and lower dose.

Indexed as

InterferometryTomography, X-Ray ComputedComputer SimulationRadiographyX-Raysbiprism interferometrydark-field imagingsmall-angle scatterX-ray phase contrast imaging

Identifiers

PMID34407202
PMCPMC8855978

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.