Evidence map›Paper›PMID 34407037›Full record

Trial reportJournal of the Chinese Medical Association : JCMA2022

A prospective, randomized study assessing different modalities for flushing totally implanted vascular access device in children with malignancy.

Hsiang-Chen Hsieh, Shu-Chen Hung, Sheng-Yang Huang, Fang-Liang Huang, Chia-Man Chou

Open access · hybridAbstract readRandomized Controlled Trial
In one paragraph

Trial report in Journal of the Chinese Medical Association : JCMA, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed, 1 pooled it
1.1field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 1 synthesis or guideline pooled it, 5 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Hsiang-Chen HsiehDepartment of Surgery, Taichung Veterans General Hospital, Taiwan, ROC.
Shu-Chen HungDepartment of Nursing, Taichung Veterans General Hospital, Taiwan, ROC.
Sheng-Yang HuangDepartment of Surgery, Taichung Veterans General Hospital, Taiwan, ROC.
Fang-Liang HuangDepartment of Pediatrics, Taichung Veterans General Hospital, Taichung, Taiwan, ROC.
Chia-Man ChouDepartment of Surgery, Taichung Veterans General Hospital, Taiwan, ROC.
Taichung Veterans General Hospital · TWNational Yang Ming Chiao Tung University · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe totally implanted vascular access device (TIVAD) is commonly used in patients with malignant tumors requiring chemotherapy or long-term intravenous infusion and those with difficulty placing peripheral venous catheters. It could also be used to draw blood in pediatric patients. Thus, how to maintain the patency and longevity of TIVAD is always emphasized.

methodsIn this prospective study, TIVAD was randomly infused in patients under 18 years with three different concentrations of heparinized solutions: 10 mL with 100 U/mL heparin, 20 mL with 10 U/mL heparin, and 30 mL with 10 U/mL heparin.

resultsA total of 81 patients (46 males and 35 females) were enrolled in this study from August 2, 2013 to February 1, 2017. The mean age of those who received TIVAD implantation was 7.2 ± 5.3 years, and the mean duration of using TIVAD was 1027.6 ± 369.1 days. Patients without catheter occlusion events experienced significantly shorter hospitalizations, fewer admissions, and fewer punctures than those with catheter occlusion events (p < 0.05). The administration and frequency of blood transfusions, history of bacteremia, and medication history did not increase the risk of catheter occlusion, but puncture frequency increased this risk. In patients with catheter occlusion events (38/81, 46.9%), catheter patency was restored after instillation of urokinase solution.

conclusionIn this study, the risk of TIVAD catheter occlusion was only related to puncture frequency regardless of the heparin flush composition or patient characteristics. A high puncture frequency of TIVAD during the 3.5-year study period significantly increased the risk of catheter occlusion. Besides, flushing and locking solutions for TIVAD using heparin at 10 U/mL was effective as using heparin at 100 U/mL regardless of the flushing volume of 10, 20, or 30 mL.

Indexed as

Catheter ObstructionNeoplasmsVascular Access DevicesChildChild, PreschoolEquipment FailureFemaleHumansMaleProspective Studies

Identifiers

PMID34407037
PMCPMC12755352
OpenAlexW3195639651

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.