Visualization of implanted mesh in the pelvic reconstructive surgery using an X-ray-detectable thread.

Hui Li, Huimin Shu, Guangfang Qiao, Zhiyuan Dai

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of gynecology and obstetrics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Review
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Hui LiDepartment of Gynecology, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, No. 2699, West Gaoke Road, Pudong New District, Shanghai, 201204, China.
Huimin ShuDepartment of Gynecology, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, No. 2699, West Gaoke Road, Pudong New District, Shanghai, 201204, China.
Guangfang QiaoDepartment of Gynecology, Songjiang Maternity and Child Health Hospital, Shanghai, China.
Zhiyuan DaiDepartment of Gynecology, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, No. 2699, West Gaoke Road, Pudong New District, Shanghai, 201204, China. popsurgery@163.com.ORCID http://orcid.org/0000-0001-9582-7681
Shanghai First Maternity and Infant Hospital · CNShanghai Changning Maternity and Infant Health Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeVisualization of the implanted mesh after a pelvic floor repair surgery is important for evaluating mesh-related complications. We made an X-ray-detectable mesh and studied the histocompatibility and toxicity of it.

methodsA thin barium sulfate thread was weaved on a traditional polypropylene mesh to make it X-ray detectable. The cytotoxicity of the mesh was tested by the MTT assay on L929 cell line. The histocompatibility and toxicity of mesh were evaluated in rabbits. Meshes were first implanted intraperitoneally. On postoperative day 7, bloods were tested to estimate the acute toxicity of meshes. After 6 months, rabbits were sacrificed and local inflammatory reaction and tissue regeneration at implantation sites were estimated by the HE stain and Masson stain. In addition, CT scans were performed after surgeries to display the location and shape of implanted meshes.

resultsCompared to the polypropylene mesh group, no significant difference was observed in the X-ray-detectable mesh group on both in vitro cytotoxicity and in vivo acute and chronic toxicity. The amounts of extra cellular matrix between two groups did not differ. Through CT scan and 3D remodeling, the barium sulfate thread clearly revealed the position and shape of the X-ray-detectable mesh, whereas the traditional mesh was invisible under CT scan.

conclusionAdding a thin barium sulfate thread on the polypropylene mesh does not change its histocompatibility or toxicity in rabbit model. The barium sulfate thread can effectively show the location and shape of implanted mesh under CT scan.

Indexed as

Plastic Surgery ProceduresSurgical MeshAnimalsMaterials TestingPolypropylenesRabbitsX-RaysPolypropylenesBarium sulfateHerniaPelvic floor dysfunctionPolypropylene meshX-ray-detectable mesh

Identifiers

PMID34405286
OpenAlexW3193791363

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.