ArticleInternational wound journal2022
Evaluation of facial tissue stresses under medical devices post application of a cyanoacrylate liquid skin protectant: An integrated experimental-computational study.
Article in International wound journal, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 4 citations in OpenAlex.
- Effect of Algoplaque Hydrocolloid Dressing Combined with Nanosilver Antibacterial Gel under Predictive Nursing in the Treatment of Medical Device-Related Pressure Injury.Computational and mathematical methods in medicine · 2022Trial
- The frictional energy absorber effectiveness and its impact on the pressure ulcer prevention performance of multilayer dressings.International wound journal · 2024Review
- Evaluation of facial tissue stresses under medical devices post application of a cyanoacrylate liquid skin protectant: An integrated experimental-computational study.International wound journal · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
Abstract
Medical device-related pressure ulcers (PUs) (injuries) are a subclass of PUs, associated with pressure and/or shear applied by a medical device onto the skin. Clinical application of a cyanoacrylate liquid skin protectant (CLSP) under the contours of skin-contacting medical devices to shield an intact skin from the sustained mechanical loads that are applied by medical devices is a preventative option, but no computer modelling work has been reported to assess the biomechanical efficacy of such interventions. Here, we investigated the biomechanical protective effect of a polymerised cyanoacrylate coating using three-dimensional, anatomically realistic finite element models of the ear with oxygen cannula and the mouth with endotracheal attachment device, informed by experimental studies. We have compared tissue stress exposures under the devices at these facial sites between conditions where the cyanoacrylate skin protectant has been applied or where the device was contacting the skin directly, without the shielding of the cyanoacrylate coating. The CLSP considerably reduced the skin stress concentration levels and overall tissue stress exposures under the aforementioned medical devices. This demonstrates strong biomechanical effectiveness of the studied cyanoacrylate-based skin protectant in prevention of facial medical device-related injuries at small, curved and thereby difficult to protect facial sites.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.