Evidence map›Paper›PMID 34401506›Full record

ArticleLaryngoscope investigative otolaryngology2021

Speech comprehension across multiple CI processor generations: Scene dependent signal processing.

Matthias Hey, Britta Böhnke, Alexander Mewes, Patrick Munder, Stefan J Mauger, Thomas Hocke

2 registry-linked trialsOpen access · goldAbstract read
In one paragraph

Article in Laryngoscope investigative otolaryngology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 15 papers.

0numbers the graph read from it
0cells of the map it votes in
15citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06734897 narecruitingnot on this mapstarted 2025, after this paper: background citation

Impact of Music Therapy on Speech Intelligibility in Noise With Cochlear Implants

TypeinterventionalSponsorArmina KreuzerRan2025 to 2027Enrolled30ConditionsMusic Therapy After Cochlear ImplantationArmsmusic therapy after Cochlear Implantation, no music therapy after Cochlear Implantation
NCT07476079 nanot yet recruitingnot on this mapstarted 2026, after this paper: background citation

Optimization and Validation of Electric Acoustic Stimulation (EAS) Mapping as a Function of Residual Hearing After CI-Implantation

TypeinterventionalSponsorLuzerner KantonsspitalRan2026 to 2027Enrolled12ConditionsFitting Methods by EAS PatientsArmsThe objective fitting method of the EAS based on the thresholds of electrocochleography is the intervention of our study., The subjective adjustment of an EAS based on thresholds from the pure tone audiogram.
3 · Its place in the literature

Who cites it

15 citing papers in PubMed, 24 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 2 countries.

Matthias HeyAudiology, ENT clinic UKSH Kiel Germany.ORCID https://orcid.org/0000-0002-7150-0833
Britta BöhnkeAudiology, ENT clinic UKSH Kiel Germany.
Alexander MewesAudiology, ENT clinic UKSH Kiel Germany.
Patrick MunderAudiology, ENT clinic UKSH Kiel Germany.
Stefan J MaugerCochlear Limited Melbourne Australia.
Thomas HockeCochlear Deutschland Hannover Germany.
University Hospital Schleswig-Holstein · DECochlear (Australia) · AU

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesIn clinical practice, characterization of speech comprehension for cochlear implant (CI) patients is typically administered by a set of suprathreshold measurements in quiet and in noise. This study investigates speech comprehension of the three most recent cochlear implant sound processors; CP810, CP910, and CP1000 (Cochlear Limited). To compare sound processor performance across generations and input dynamic range changes, the state-of-the art signal processing technologies available in each sound processor were enabled. Outcomes will be assessed across a range of stimulation intensities, and finally analyzed with respect to normal hearing listeners.

methodsIn a prospective study, 20 experienced postlingually deafened CI patients who received a Nucleus CI in the ENT department of the University Hospital of SH in Kiel were recruited. Speech comprehension was measured in quiet at 40, 50, and 65 dB

resultsWe found that high levels of open-set speech comprehension are achieved at suprathreshold presentation levels in quiet. However, results at lower test levels have remained mostly unchanged for tested sound processors with default dynamic range. Expanding the lower limit of the acoustic input dynamic range yields better speech comprehension at lower presentation levels. In noise the application of ForwardFocus improves the speech reception. Overall, a continuous improvement for speech perception across three generations of CI sound processors was found.

conclusionsFindings motivate further development of signal pre-processing, an additional focus of clinical work on lower stimulation levels, and automation of ForwardFocus. LEVEL OF EVIDENCE: 2.

Indexed as

Cochlear implantForwardFocusnoise reductionsignal processingspeech audiometryspeech intelligibility

Identifiers

PMID34401506
PMCPMC8356868
OpenAlexW3170072105

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.