ArticleJournal of healthcare engineering2021
Structural Design and Preliminary Tests of a Novel Patient Transfer Apparatus for Medical Scenarios.
Article in Journal of healthcare engineering, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Patient transfer has always been a difficult problem, usually requiring multiple caregivers to work together, which is time consuming and can easily cause secondary injuries to the patient. In addition, with the crisis of COVID-19, the issue of patient transfer is even more critical, as caregivers are at a high risk of infection, causing significant damage to healthcare resources. In this paper, a patient transfer assist system named E-pat-plus (Easy Patient Transfer plus) has been proposed; it can assist caregivers in transferring patients, reduce direct contact between them, and avoid secondary injuries. In the mechanical structure of this apparatus, a novel five-gear assembly module and a synchronous belt pulley set are proposed; they are the key points to the basic functional realization of the device and can reduce the cost of the prototype. Furthermore, a fuzzy (proportion-integration-differentiation) PID-based cross-coupling control strategy is applied to the apparatus to ensure the stability and safety of the operation. Finally, some preliminary experiments, including current experiments and error experiments, are carried out to verify the reliability of the device and lay the foundation for clinical tests.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.