ArticleTanaffos2021
Effects of Chlorine Gas Exposure and Associated Factors on Spirometric Parameters in Detergent Industry Workers: a Four-Year Cross-Sectional Study.
Article in Tanaffos, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 3 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThis study aimed to determine the effects of chlorine gas exposure and the associated factors on spirometric parameters among detergent industry workers in Semnan, Iran. MATERIALS AND
methodsThis four-year cross-sectional study was concocted on 100 workers of two detergent factories in Semnan, Iran. Two questionnaires were used for data collection. The first questionnaire included demographic and occupational information, and the second questionnaire included spirometric parameters, such as forced vital capacity (FVC), forced expiratory volume in one second (FEV1), FEV1/FVC ratio, peak expiratory flow (PEF), and PEF 25-75%. The spirometric parameters were measured over four consecutive years by a trained technician. Next, to determine the effects of chlorine gas exposure and its associated factors on spirometric parameters, a generalized estimating equation (GEE) model was used. The correlation structure of GEE was considered to be autoregressive 1 (AR-1). Analyses were performed in STATA version 14.
resultsAll spirometric parameters showed a decreasing trend during 2012-2015. The GEE model showed a significant association between chlorine gas exposure and all spirometric parameters; the beta-coefficients for the effect of exposure (year) on FVC, FEV1, FEV1/FVC ratio, PEF, and PEF 25-75% were -4.51, -6.46, -4.27, -6.09, and -10.29, respectively. Also, this model demonstrated a significant association between smoking and FEV1, PEF, and PEF 25-75%; the beta-coefficients for the effect of smoking on these parameters were -5.64, -8.88, and -5.75, respectively. Additionally, the GGE model showed a significant association between the body mass index (BMI) and FVC and FEV1 (P<0.05); the beta-coefficients for the effect of BMI on these two parameters were - 0.59 and -0.48, respectively.
conclusionThe spirometric parameters showed a decreasing trend over time among detergent industry workers; this decline was more remarkable among individuals with a history of smoking. Therefore, it seems necessary to implement screening programs and periodic active examinations for these workers.
Indexed as
Identifiers
34394369PMC8355941W3194057876What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.