Evidence map›Paper›PMID 34390388›Full record

ArticleArchives of orthopaedic and trauma surgery2022

Cementless total hip arthroplasty with anatomic-shaped implants. Does the minimal invasive anterolateral technique influence the stem position or subsidence in contrast to the standard lateral approach?

Nils Wirries, Marcus Örgel, Michael Schwarze, Stefan Budde, Henning Windhagen, Michael Skutek

Abstract read
PubMed Publisher
In one paragraph

Article in Archives of orthopaedic and trauma surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nils WirriesDepartment of Orthopaedic Surgery at Diakovere Annastift, Hannover Medical School, Hannover, Germany. Nils.Wirries@ocm-muenchen.de.ORCID http://orcid.org/0000-0002-5938-2096
Marcus ÖrgelTrauma Department, Hannover Medical School, Hannover, Germany.
Michael SchwarzeLaboratory for Biomechanics and Biomaterials, Hannover Medical School, Hannover, Germany.
Stefan BuddeDepartment of Orthopaedic Surgery at Diakovere Annastift, Hannover Medical School, Hannover, Germany.
Henning WindhagenDepartment of Orthopaedic Surgery at Diakovere Annastift, Hannover Medical School, Hannover, Germany.
Michael SkutekDepartment of Orthopaedic Surgery at Diakovere Annastift, Hannover Medical School, Hannover, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionUsing cementless stems in total hip arthroplasty (THA) has revealed variable results. The risk for early aseptic loosening has been associated to certain surgical approaches and implant designs. This study determines misalignment of collared/collarless stems and the rate of subsidence using the anterolateral approach (ALA) compared to implantations via the direct lateral approach (DLA). MATERIALS AND

methodsOne hundred consecutive patients underwent primary unilateral THA using the minimal invasive ALA in the lateral decubitus position and were compared to another cohort of 100 patients, treated trough the DLA. Clinical results were noted preoperatively and after 1 year using the WOMAC score. The radiographic evaluation included the stem alignment and subsidence.

resultsOverall, all patients improved in WOMAC from 48.9 points (± 11.4; 21.0-82.0) to 3.1 (± 3.2; 0.0-22.0) (p < 0.001). For DLA and ALA, the stem was placed on average 2.5° in varus to the femoral axis. The mean alignment was about 0.5° more valgus for collarless stems. The mean subsidence in the DLA group was about 0.3 mm higher compared to the ALA group. With collarless implants, the subsidence was about 1.0 mm higher compared to collared implants (p < 0.05), especially in patients with Dorr type B femurs.

conclusionsChanging from the DLA to the minimal invasive ALA did not significantly affect the implant position. Misalignment and a potential risk for early aseptic loosening could not be seen. The use of a collared cementless stem seems safe and is likely to prevent a relevant subsidence, even more so in Dorr type B femurs. LEVEL OF EVIDENCE: III.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisFemurHumansLower ExtremityProsthesis DesignAlignmentAnterolateral approachCollaredMinimally invasive hip arthroplastySubsidenceWOMAC

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.