Evidence map›Paper›PMID 34390104›Full record

ArticleAngewandte Chemie (International ed. in English)2021

Automated Electrical Quantification of Vitamin B1 in a Bodily Fluid using an Engineered Nanopore Sensor.

Florian Leonardus Rudolfus Lucas, Tjemme Rinze Cornelis Piso, Nieck Jordy van der Heide, Nicole Stéphanie Galenkamp, Jos Hermans, Carsten Wloka, Giovanni Maglia

Open access · hybridAbstract read
In one paragraph

Article in Angewandte Chemie (International ed. in English), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.1field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 36 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Florian Leonardus Rudolfus LucasGroningen Biomolecular Sciences and Biotechnology Institute, University of Groningen, Groningen, 9747, AG Groningen, Netherlands.
Tjemme Rinze Cornelis PisoGroningen Biomolecular Sciences and Biotechnology Institute, University of Groningen, Groningen, 9747, AG Groningen, Netherlands.
Nieck Jordy van der HeideGroningen Biomolecular Sciences and Biotechnology Institute, University of Groningen, Groningen, 9747, AG Groningen, Netherlands.
Nicole Stéphanie GalenkampGroningen Biomolecular Sciences and Biotechnology Institute, University of Groningen, Groningen, 9747, AG Groningen, Netherlands.
Jos HermansAnalytical Biochemistry, Department of Pharmacy, University of Groningen, Antonius Deusinglaan 1, Groningen, 9713, AV, The Netherlands.
Carsten WlokaGroningen Biomolecular Sciences and Biotechnology Institute, University of Groningen, Groningen, 9747, AG Groningen, Netherlands.ORCID 0000-0003-0487-3311
Giovanni MagliaGroningen Biomolecular Sciences and Biotechnology Institute, University of Groningen, Groningen, 9747, AG Groningen, Netherlands.
University of Groningen · NL

Funding

h2020 european research council DeE-Nanonederlandse organisatie voor wetenschappelijk onderzoek 722.017.010stichting voor fundamenteel onderzoek der materie
6 · The paper itself

Abstract

The ability to measure the concentration of metabolites in biological samples is important, both in the clinic and for home diagnostics. Here we present a nanopore-based biosensor and automated data analysis for quantification of thiamine in urine in less than a minute, without the need for recalibration. For this we use the Cytolysin A nanopore and equip it with an engineered periplasmic thiamine binding protein (TbpA). To allow fast measurements we tuned the affinity of TbpA for thiamine by redesigning the π-π stacking interactions between the thiazole group of thiamine and TbpA. This substitution resulted furthermore in a marked difference between unbound and bound state, allowing the reliable discrimination of thiamine from its two phosphorylated forms by residual current only. Using an array of nanopores, this will allow the quantification within seconds, paving the way for next-generation single-molecule metabolite detection systems.

Indexed as

NanoporesBiosensing TechniquesBody FluidsCarrier ProteinsElectricityHumansNanotechnologyPerforinProtein BindingThiamineCarrier ProteinsPerforinThiaminethiamine-binding proteinbayesianbiosensorsnanoporesnanotechnologythiamine

Identifiers

PMID34390104
PMCPMC8518494
OpenAlexW3191434066

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.