Factors affecting signal quality in implantable cardiac monitors with long sensing vector.

Giovanni B Forleo, Claudia Amellone, Riccardo Sacchi, Leonida Lombardi, Maria Teresa Lucciola, Valentina Scotti, Maurizio Viecca, Marco Schiavone, Daniele Giacopelli, Massimo Giammaria

Open access · goldAbstract read
In one paragraph

Article in Journal of arrhythmia, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Trial
  2. Article
  3. Implantation of a novel insertable cardiac monitor: preliminary multicenter experience in Europe.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2024
    Review
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 4 institutions in 1 country.

Giovanni B ForleoCardiology Unit ASST-Fatebenefratelli Sacco Luigi Sacco University Hospital Milan Italy.ORCID https://orcid.org/0000-0001-8895-8915
Claudia AmelloneCardiology Unit Ospedale Maria Vittoria Turin Italy.
Riccardo SacchiCardiology Unit Ospedale di Vimercate Vimercate, Milan Italy.
Leonida LombardiCardiology Unit ASST-Fatebenefratelli Sacco Luigi Sacco University Hospital Milan Italy.
Maria Teresa LucciolaCardiology Unit Ospedale Maria Vittoria Turin Italy.
Valentina ScottiCardiology Unit Ospedale di Vimercate Vimercate, Milan Italy.
Maurizio VieccaCardiology Unit ASST-Fatebenefratelli Sacco Luigi Sacco University Hospital Milan Italy.
Marco SchiavoneCardiology Unit ASST-Fatebenefratelli Sacco Luigi Sacco University Hospital Milan Italy.ORCID https://orcid.org/0000-0003-0720-3380
Daniele GiacopelliClinical Research Unit BIOTRONIK Italia Vimodrone, Milan Italy.ORCID https://orcid.org/0000-0003-1584-7944
Massimo GiammariaCardiology Unit Ospedale Maria Vittoria Turin Italy.ORCID https://orcid.org/0000-0001-5070-7715
ASST Fatebenefratelli Sacco · ITOspedale Maria Vittoria · ITAzienda Ospedaliera di Desio e Vimercate · ITUniversity of Padua · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeElectrical artefacts are frequent in implantable cardiac monitors (ICMs). We analyzed the subcutaneous electrogram (sECG) provided by an ICM with a long sensing vector and factors potentially affecting its quality.

methodsConsecutive ICM recipients underwent a follow-up where demographics, body mass index (BMI), implant location, and surface ECG were collected. The sECG was then analyzed in terms of R-wave amplitude and P-wave visibility.

resultsA total of 84 patients (43% female, median age 68 [58-76] years) were enrolled at 3 sites. ICMs were positioned with intermediate inclination (n = 44, 52%), parallel (n = 35, 43%), or perpendicular (n = 5, 6%) to the sternum. The median R-wave amplitude was 1.10 (0.72-1.48) mV with P waves readily visible in 69.2% (95% confidence interval, CI: 57.8%-79.2%), partially visible in 23.1% [95% CI: 14.3%-34.0%], and never visible in 7.7% [95% CI: 2.9%-16.0%] of patients. Men had higher R-wave amplitudes compared to women (1.40 [0.96-1.80] mV vs 1.00 [0.60-1.20] mV,

conclusionIn ordinary clinical practice, ICMs with long sensing vector provided median R-wave amplitude above 1 mV and reliable P-wave visibility of nearly 70%, regardless of the position of the device. Women and obese patients showed lower but still very good signal quality.

Indexed as

implantable cardiac monitorimplantable loop recorderlong sensing vectorP‐wave visibilityR‐wave amplitude

Identifiers

PMID34386133
PMCPMC8339108
OpenAlexW3176705611

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.