ArticleMedical science monitor : international medical journal of experimental and clinical research2021
Using the Diaphragm as a Tracking Surrogate in CyberKnife Synchrony Treatment.
Article in Medical science monitor : international medical journal of experimental and clinical research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
6 citing papers in PubMed, 7 citations in OpenAlex.
- Intra-respiratory variation in tumour-diaphragm geometric association as a potential surrogate for dynamic tumour-tracking radiotherapy.Physics and imaging in radiation oncology · 2026Article
- Article
- Clinical application of a GPU-accelerated monte carlo dose verification for cyberknife M6 with Iris collimator.Radiation oncology (London, England) · 2024Article
- Novel utilization and quantification of Xsight diaphragm tracking for respiratory motion compensation in Cyberknife Synchrony treatment of liver tumors.Journal of applied clinical medical physics · 2024Article
- Markerless dynamic tumor tracking (MDTT) radiotherapy using diaphragm as a surrogate for liver targets.Journal of applied clinical medical physics · 2024Article
- Development and evaluation of ultrasound image tracking technology based on Mask R-CNN applied to respiratory motion compensation system.Quantitative imaging in medicine and surgery · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
BACKGROUND In this study, we assessed the usefulness of diaphragm surrogate tracking in the design of a respiratory model for CyberKnife Synchrony treatment of lung tumors. MATERIAL AND METHODS Twenty-four patients with lung cancer who underwent stereotactic body radiotherapy with CyberKnife between April and November 2019 were enrolled. Simulation plans for each patient were designed using Xsight lung tracking (XLT) and diaphragm tracking (DT) methods, and tumor visualization tests were performed. The offset consistency at each respiratory phase was analyzed. The relative distance along the alignment center of the superior-inferior (SI) axis in the 2 projections (dxAB), uncertainty (%), and average standard error (AvgStdErr)/maximum standard error (MAXStdErr) were also analyzed. RESULTS Bland-Altman analyses revealed that the average differences±standard deviation (SD) between XLT and DT tracking methods were 0.4±2.9 mm, 0.3±4.35 mm, and -1.8±6.8 mm for the SI, left-right (LR), and anterior-posterior (AP) directions, respectively. These results indicated high consistency in the SI and LR directions and poor consistency in the AP direction. Uncertainty differed significantly between XLT and DT (22.813±5.721% vs 9.384±3.799%; t=-5.236; P=0.0008), but we found no significant differences in dxAB, AvgStdErr, or MAXStdErr. CONCLUSIONS In the majority of cases, motion tracking by XLT and DT was consistent and synchronized in the SI directions, but not in the LR and AP directions. With a boundary margin of 0.3±4.35 mm and 1.8±6.8 mm for the LR and AP directions, DT may contribute to better implementation of CyberKnife Synchrony treatment in patients with lung tumors near the diaphragm that cannot be seen in tumor visualization tests.
Indexed as
Identifiers
What OpenQuestion holds