Evidence map›Paper›PMID 34378308›Full record

ArticleJournal of applied clinical medical physics2021

How does CBCT reconstruction algorithm impact on deformably mapped targets and accumulated dose distributions?

Weihua Mao, Chang Liu, Stephen J Gardner, Mohamed Elshaikh, Ibrahim Aref, Joon K Lee, Deepak Pradhan, Farzan Siddiqui, Karen Chin Snyder, Akila Kumarasiri and 6 more

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

16 authors.

Weihua MaoHenry Ford Health System, Detroit, MI, USA.ORCID https://orcid.org/0000-0001-5985-4244
Chang LiuHenry Ford Health System, Detroit, MI, USA.
Stephen J GardnerHenry Ford Health System, Detroit, MI, USA.ORCID https://orcid.org/0000-0001-6656-902X
Mohamed ElshaikhHenry Ford Health System, Detroit, MI, USA.
Ibrahim ArefHenry Ford Health System, Detroit, MI, USA.
Joon K LeeHenry Ford Health System, Detroit, MI, USA.
Deepak PradhanHenry Ford Health System, Detroit, MI, USA.
Farzan SiddiquiHenry Ford Health System, Detroit, MI, USA.
Karen Chin SnyderHenry Ford Health System, Detroit, MI, USA.
Akila KumarasiriHenry Ford Health System, Detroit, MI, USA.
Bo ZhaoHenry Ford Health System, Detroit, MI, USA.
Joshua KimHenry Ford Health System, Detroit, MI, USA.ORCID https://orcid.org/0000-0001-8371-2852
Haisen LiHenry Ford Health System, Detroit, MI, USA.
Ning Winston WenHenry Ford Health System, Detroit, MI, USA.ORCID https://orcid.org/0000-0001-9776-8056
Benjamin MovsasHenry Ford Health System, Detroit, MI, USA.
Indrin J ChettyHenry Ford Health System, Detroit, MI, USA.

Funding

Varian Medical Systems (Varian)
6 · The paper itself

Abstract

purposeWe performed quantitative analysis of differences in deformable image registration (DIR) and deformable dose accumulation (DDA) computed on CBCT datasets reconstructed using the standard (Feldkamp-Davis-Kress: FDK_CBCT) and a novel iterative (iterative_CBCT) CBCT reconstruction algorithms.

methodsBoth FDK_CBCT and iterative_CBCT images were reconstructed for 323 fractions of treatment for 10 prostate cancer patients. Planning CT images were deformably registered to each CBCT image data set. After daily dose distributions were computed, they were mapped to planning CT to obtain deformed doses. Dosimetric and image registration results based CBCT images reconstructed by two algorithms were compared at three levels: (A) voxel doses over entire dose calculation volume, (B) clinical constraint results on targets and sensitive structures, and (C) contours propagated to CBCT images using DIR results based on three algorithms (SmartAdapt, Velocity, and Elastix) were compared with manually delineated contours as ground truth.

results(A) Average daily dose differences and average normalized DDA differences between FDK_CBCT and iterative_CBCT were ≤1 cGy. Maximum daily point dose differences increased from 0.22 ± 0.06 Gy (before the deformable dose mapping operation) to 1.33 ± 0.38 Gy after the deformable dose mapping. Maximum differences of normalized DDA per fraction were up to 0.80 Gy (0.42 ± 0.19 Gy). (B) Differences in target minimum doses were up to 8.31 Gy (-0.62 ± 4.60 Gy) and differences in critical structure doses were 0.70 ± 1.49 Gy. (C) For mapped prostate contours based on iterative_CBCT (relative to standard FDK_CBCT), dice similarity coefficient increased by 0.10 ± 0.09 (p < 0.0001), mass center distances decreased by 2.5 ± 3.0 mm (p < 0.00005), and Hausdorff distances decreased by 3.3 ± 4.4 mm (p < 0.00015).

conclusionsThe new iterative CBCT reconstruction algorithm leads to different mapped volumes of interest, deformed and cumulative doses than results based on conventional FDK_CBCT.

Indexed as

Spiral Cone-Beam Computed TomographyAlgorithmsCone-Beam Computed TomographyHumansImage Processing, Computer-AssistedMaleRadiometryRadiotherapy Planning, Computer-Assisteddeformable dose accumulationiCBCT

Identifiers

PMID34378308
PMCPMC8425863

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.