Evidence map›Paper›PMID 34376937›Full record

ArticleIndian journal of nephrology

Prevalence of Clinically Significant anti-HLA Antibodies in Renal Transplant Patients: Single-center Report from North India.

Rajni Chauhan, Aseem Kumar Tiwari, Chhavi Rajvanshi, Simmi Mehra, Abhishek Saini, Geet Aggarwal, Shyam Bihari Bansal, Vijay Kher, Shoma Paul Nandi

Open access · diamondAbstract read
In one paragraph

Article in Indian journal of nephrology. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 6 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 1 institution in 1 country.

Rajni ChauhanAmity Institute of Biotechnology, Amity University Uttar Pradesh, Noida, Uttar Pradesh, India.
Aseem Kumar TiwariDepartment of Transfusion Medicine, Molecular and Transplant Immunology Laboratory, Medanta-The Medicity, Gurugram, Haryana, India.
Chhavi RajvanshiDepartment of Transfusion Medicine, Molecular and Transplant Immunology Laboratory, Medanta-The Medicity, Gurugram, Haryana, India.
Simmi MehraDepartment of Transfusion Medicine, Molecular and Transplant Immunology Laboratory, Medanta-The Medicity, Gurugram, Haryana, India.
Abhishek SainiDepartment of Transfusion Medicine, Molecular and Transplant Immunology Laboratory, Medanta-The Medicity, Gurugram, Haryana, India.
Geet AggarwalDepartment of Transfusion Medicine, Molecular and Transplant Immunology Laboratory, Medanta-The Medicity, Gurugram, Haryana, India.
Shyam Bihari BansalDepartment of Nephrology and Transplant Medicine, Medanta-The Medicity, Gurugram, Haryana, India.
Vijay KherDepartment of Nephrology and Transplant Medicine, Medanta-The Medicity, Gurugram, Haryana, India.
Shoma Paul NandiAmity Institute of Biotechnology, Amity University Uttar Pradesh, Noida, Uttar Pradesh, India.
Amity University · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionSolid organ transplantation is the preferred therapeutic modality of treatment in patients affected by terminal organ failures. Human leukocyte antigens (HLAs) plays an important role in graft survival. In many of the cases of rejection, antibodies are directed against HLA antigens expressed on the cells of the transplanted organ. Pre-transplant compatibility testing involves the use of different methodologies for the determination of anti-HLA antibodies. Luminex single-antigen bead (SAB) assay demonstrates higher sensitivity and specificity in detecting anti-HLA antibodies. The aim of this study was to determine the prevalence of anti-HLA antibodies in pre-transplant work up recipients, planned for renal transplant at a tertiary care center in India.

methods1640 patients visiting tertiary care hospital for pre-transplant compatibility testing were screened with complement-dependent micro-lymphocytotoxicity crossmatch (CDC-XM) and flow cytometric crossmatch (FC-XM). The patients positive for either or both screening tests were assayed with the Luminex SAB tests in order to establish defined antigen specificity of the alloantibodies and determining donor-specific antibody (DSA).

resultsThe two most frequent antibodies identified in each A, B, C locus of HLA class I were -A*24:03 (43.9%), A*25:01 (36.6%), B*57:01 (40.3%), B*15:12 (37.1%), C*17:01 (61.9%), C*07:01 (52.4%) and in DR, DQ DP locus in HLA class II were DRB1*09:01(40.0%), DRB1*14:04(37.6%), DQA1*04:01/DQB1*03:03 (58.4%), DQA1*05:01/DQB1*03:01 (55.1%), DPA1*02:01/DPB1*17:01 (55.0%), DPA1*02:01/DPB1*05:01 (45.0%).

conclusionThis study has found the prevalence and specificity of anti-HLA antibodies in north India.

Indexed as

CDC crossmatchDSAHLArenal transplantsingle-antigen bead assay

Identifiers

PMID34376937
PMCPMC8330640
OpenAlexW3147931237

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.