Evidence map›Paper›PMID 34376106›Full record

ArticleInternational journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group2021

Computer simulations of an irrigated radiofrequency cardiac ablation catheter and experimental validation by infrared imaging.

Christian Rossmann, Anjan Motamarry, Dorin Panescu, Dieter Haemmerich

Abstract read
In one paragraph

Article in International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Role of Computational Modelling in Enhancing Thermal Safety During Cardiac Ablation.Interdisciplinary cardiovascular and thoracic surgery · 2025
    Review
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Christian RossmannDepartment of Pediatrics, Medical University of South Carolina, Charleston, SC, USA.
Anjan MotamarryDepartment of Pediatrics, Medical University of South Carolina, Charleston, SC, USA.ORCID 0000-0003-2964-9658
Dorin PanescuBiotronik, Santa Clara, CA, USA.
Dieter HaemmerichDepartment of Pediatrics, Medical University of South Carolina, Charleston, SC, USA.ORCID 0000-0003-1127-7024

Funding

EXTRAMURAL RESEARCH FACILITIES CONSTRUCTIONC06RR018823 · NCRR · MEDICAL UNIVERSITY OF SOUTH CAROLINA · PI RAYMOND, JOHN R · 2003 to 2003
$2.9M
MUSC FACIL EXPANSION &RENOV: SLE C06RR015455 · NCRR · MEDICAL UNIVERSITY OF SOUTH CAROLINA · PI RAYMOND, JOHN R · 2002 to 2002
$2.0M
NCRR NIH HHS C06 RR015455NCRR NIH HHS C06 RR018823
6 · The paper itself

Abstract

purposeTo develop and validate a three-dimensional (3-D) computer model based on accurate geometry of an irrigated cardiac radiofrequency (RF) ablation catheter with microwave radiometry capability, and to test catheter performance.

methodsA computer model was developed based on CAD geometry of a RF cardiac ablation catheter prototype to simulate electromagnetic heating, heat transfer, and computational fluid dynamics (blood flow, open irrigation, and natural convection). Parametric studies were performed; blood flow velocity (0-25 cm/s) and irrigation flow (0-40 ml/min) varied, both with perpendicular (PE) and parallel (PA) catheter orientations relative to tissue. Tissue Agar phantom studies were performed under similar conditions, and temperature maps were recorded

resultsModel predicted thermal lesion width at 5 W power was 5.8-6.4 mm (PE)/6.5-6.6 mm (PA), and lesion depth was 4.0-4.3 mm (PE)/4.0-4.1 mm (PA). Compared to phantom studies, the mean errors of the computer model were as follows: 6.2 °C(PE)/4.3 °C (PA) for maximum gel temperature, 0.7 mm (10.9%) (PE)/0.1 mm (0.8%) (PA) for lesion width, and 0.3 mm (7.7%)(PE)/0.7 mm (19.1%) (PA) for lesion depth. For temperature-controlled ablation, model predicted thermal lesion width was 7-9.2 mm (PE)/8.6-9.2 mm (PA), and lesion depth was 4.3-5.5 mm (PE)/3.4-5.4 mm (PA).

conclusionsComputer models were able to reproduce device performance and to enable device evaluation under varying conditions. Temperature controlled ablation of irrigated catheters enables optimal tissue temperatures independent of patient-specific conditions such as blood flow.

Indexed as

Catheter AblationCathetersComputer SimulationHeartHumansTemperaturecardiac catheter ablationEMheat transferintegratedmodeling (i.e.Radiofrequency/microwavethermal ablationtreatment planning)ultrasound